HTE402559
35/47
Note 1: After stored the stroke the partsfeeder runs by it even if the external signal “N1”
and “N2” are changed.
Data of stroke, drive frequency, soft start ramp-up time and on delay and off delay
times are stored for each Combination No.
Note 2:When the drive frequency is reset on Combination No.1 to 3, the partsfeeder must
be stopped and then change the external signals “N1” and “N2”.
How to store the Speed Change Signal
Please follow the procedure below to set the Combination No.1 to No.3.
The procedure must start on the Combination No.0 or open the terminals “Com” and“N1”,
and “Com” and “N2”.
1.
Set and save the stroke on the Combination No.0.
2.
Running the partsfeeder, input the external signal “N1” and “N2” according to
the Combination No.
After the action the Combination No. appears on the display as “SP-X” for “X=1
or 2 or 3” for two seconds.
The drive frequency is that is set on the Combination No.0.
Caution: If the input signal “N1” and “N2” are changed while the partsfeeder is
stopping the drive frequency stored is cleared and replaced with
the maximum.
3.
Dial the setting dial and select “Stroke” and set the stroke required with
the setting encoder.
4.
Push “Save” button to store the data. After that the Combination No. stored appears
on the display for two seconds as “SP-X” for “X=1, 2, 3”.