Step 8
Use the
Download
option from the
Programming
menu to download specific
Page
data or
All
programming data
to the Panel.
Full Remote download will take approximately 7 minutes.
Use the
Upload
option from the
Programming
menu to upload and view specific
Page
data or
All
programming
data from
the Panel.
Step 9
Select
On-hook
from the
Modem
menu to end the connection.
Software
messages
The connection status will be shown in the box at the bottom of the
Connection management
page. The following
table shows the messages and meanings.
OmniaMod v. x.xx
This is the modem release connected to the computer serial port.
Modem not recognized
The modem is not recognized on the selected serial port. Check the cable and
the selected serial port (see
Serial ports----
Options
menu).
Receiving....
The Modem / Computer system is waiting for an incoming call. This will be the
system status when the page opens.
RING
Rings detected on the telephone line.
BACK RING
This confirms that the dialled telephone is ringing.
NORMA ACK
NormaCom Panel acknowledged.
OMNIA ACK
Omnia or
Academy40
Panel acknowledged.
Installer Code reading error
The Panel cannot read the PIN----probably due to the poor quality signal on the
telephone line.
Failed Connection
It is impossible to communicate with the Panel----probably due to the poor quality
signal on the telephone line.
Refer to the
Programming from on-site computer
paragraph for the downloading instructions.
Programming from Keypad
The parameters in this section can be programmed via keypad, by means of the following options from the
IN-
STALLER
MENU.
r
Tel.Numb.Progr. (Telephone Number Programming)
r
Descript.Progr. (Description Programming)
r
Installer code
r
User codes
r
Parameter progr. (Parameter Programming)
Digital-key coding
and
Voice-message recording
can be done via keypad
only
. These functions can be ac-
cessed from the INSTALLER MENU through:
r
Voice functions
r
digital keys
Reset default
To reset the factory default programming:
Ø
disconnect the Main unit power supply (both mains power and battery)
Ø
remove the jumper
7
(MEM)
Ø
wait for at least 20 seconds
Ø
replace the jumper
7
(MEM)
Ø
connect the Main unit power supply (refer to
Power supply connection
).
ATTENTION
Jumper
7
MEM
must be disconnected for at least 20 seconds
in order to ensure full reset of the
factory default programming, and to avoid problems that may occur when the power supply is reconnected to the
Main unit.
Installer code
locked
If the
Lock Installer code
option is programmed, the Installer PIN will not be reset to factory default (refer to
Lock
Installer code
in the
Options
paragraph).
62