Code attributes programmed by the Installer
The attributes determine how the User code can operate the system (refer to
Enable on Partitions
----
Enable user
menu
----
Enable instant actions
).
Available
Only
Available
User codes can operate the system.
The system usually requires less than the 31 User codes provided. This time-saving option allows the Installer to
make only the required number of User codes
Available
to operate the system. Without this option it would be
necessary to change all the default PINs for security reasons.
+
A programmed Code that is not
Available
can be considered inexistent.
Master code
----All User codes must have a
Master
code.
----User codes with
Master
status will automatically become
Available
and
Active
.
----The
Available
and
Active
status of
Master
codes cannot be changed.
----User codes
1
through
24
can be
Master
codes.
----User codes
25
through
31
cannot be
Master
codes.
----A code can be its own Master, and therefore, can change its own
PIN
.
----A code can be Master of several codes but
Slave of only one.
----Only a
Master
code can change the
Active
status
and
PIN
of its
Slave
code.
----A Slave code must be disabled (made not
Active
) by its current
Master
code before it can be given a new
Mas-
ter
code (refer to
User parameters
).
+
The Installer cannot change the
Available
status of an
Active
User code via computer.
n
User Parameters
These parameters are usually programmed by the User. However, if Installer intervention is preferred, the User
must provide the Installer with the
Master code PIN
.
Ø
Active:
this option allows the Installer to disable a User code via computer (
Master code PIN
required).
Ø
PIN:
this option allows the Installer to change a User code PIN via computer
(
Master code PIN
required).
Enable on
partitions
Enabled User codes can control: Arming / Disarming, Stop Alarm and Bypass zone operations on their partitions.
Yes
= User code
Enabled
on the corresponding partition
Box clear = User code disabled on the corresponding partition
Row
A
is for the partitions that will arm
(
A
) or disarm (
D
) when the User code is entered at a keypad, and
is
pressed (Type A arming mode).
Row
B
is for the partitions that will arm (
A
) or disarm (
D
) when the User code is entered at a keypad, and
is
pressed (Type B arming mode).
The enabled partitions will arm or disarm when the User code is entered at a keypad, and
or
is pressed.
Enable User menu
The User menu will provide the enabled options
only
. Enable / Disable the following options, as per requirements.
Ø
Arm / Disarm:
arms / disarms partitions separately
Ø
Panel reset:
resets / stops alarms on panel
Ø
Partitions reset:
resets / stops alarms on partitions
Ø
View / Bypass zones:
views / bypasses zones
Ø
View:
views the event buffer
Ø
Teleservice:
teleservice
Ø
Clear call queue:
clears telephone-call queue
Ø
Output management:
enables /disables outputs
The enabled options will be shown on the corresponding User menu. However, in particular instances the
Tele-
serv.
,
Panel reset
and
Partition reset
will perform as follows.
+
If
Teleservice
is disabled the
Teleserv.
,
En./Dis.Teleser.
and
En./Dis.Answer
options will not appear on the
User menu.
+
Enablement of the
Panel reset
and
Partitions reset
options determines the actions the Panel will perform when
Alarm reset
or
Stop alarm
is selected from the User menu.
54