prEN 50165 - 1995
Electrical Equipment of non-electric heating
appliances for household and similar purposes,
safety requirements
1.1 Certificates of conformity
Certificates are available from the Quality Control
Department at Benson Heating.
1.2 General product information
The Benson MH 300 model has an output of
300kW.
The MH 300 units can suit either ducted
applications, or be used as free blowing units, but
each heater must be connected to its own
individual open flue.
Each heater is fitted with a forced draught burner
which has been test fired and pre-set prior to
dispatch. The safety functions of the burner are by
way of a fully sequential control box fitted to the
burner.
Note
Neither asbestos nor soft soldered joints are used
in the construction or manufacture of the Benson
range of Cabinet Heaters. The materials selected
for use can withstand the mechanical, chemical,
and thermal stresses which they will be subject to
during foreseen normal use when installed in
accordance with the manufacturers
recommendations.
1.3 General requirements
Caution
Ensure that the fuel supply is in accordance with
the manufacturer's recommendations and is as
stated on the appliance data plate.
Installation, commissioning, and servicing must
only be carried out by appropriately qualified and
competent persons.
Warning
Unauthorised modifications to the appliance, or
departure from the manufacturers guidance on
intended use, or, installation contrary to the
manufacturers recommendations may constitute a
hazard.
Note
To ignore the warning and caution notices, and to
ignore the advice from the manufacturer on
installation, commissioning, servicing, or use, will
jeopardise any applicable warranty, moreover,
such a situation could also compromise the safe
and efficient running of the appliance itself, and
thereby constitute a hazard.
The installation of the appliance must meet all the
relevant European, National, and Local criteria.
Caution
The heater must not be installed where high wind
velocities may affect burner operation. Suitable
protection should be provided for the appliance
when it is located in a position where it may be
susceptible to external mechanical damage from;
for example, fork lift trucks,
1.4 Delivery and pre-installation checks
The heater is supplied wrapped in heavy duty
protective polythene. On receipt of the heater, the
following checks should be carried out;
a) The model is as per order
b) That it is undamaged
c) That it is suitable for the fuel supply
d) That it is suitable for the electrical supply
If any of these points are not satisfied then contact
should be made with the Sale
s
Office at Benson
Heating as soon as possible by telephoning 01547-
528534. In the case of claims for damage, this
must be reported in writing within 24 hours of
delivery, in order to comply with insurance criteria