Bennett Site Master Instruction Manual 

Safety Instructions 

 

IMPORTANT SAFETY INSTRUCTIONS 

For  safe  installation  of  this  equipment,  read  and  understand  all  dangers,  warnings,  cautionary,  and  important  information.  Save  these 
important safety instructions in a readily accessible location. Look for the following warnings throughout the manual:  

Red and White 

“DANGER” 

means: If you do not follow the instructions, severe injury or death will occur. 

Orange and Black 

“WARNING” 

means: If you do not follow the instructions, severe injury or death can occur. 

Yellow and Black 

“CAUTION” 

means: If you do not follow the instructions, damage can occur to the dispenser. 

Blue and White “

IMPORTANT” 

means: Helpful tips and other recommendations on equipment installation, usage, and maintenance 

should be observed. 

DANGER 

PELIGRO 

DANGER 

 

FIRE, EXPLOSION, INJURY, OR DEATH WILL OCCUR IF FUEL FILTERS ARE CHANGED BY UNTRAINED PERSONNEL. 
MAKE SURE, ONLY TRAINED PERSONNEL CHANGE FILTERS. 

 

TO PREVENT INJURY TO YOU FROM VEHICLES AND ONLOOKERS, ALWAYS PLACE A BARRIER AROUND THIS 
EQUIPMENT BEFORE PERFORMING SERVICE OR MAINTENANCE. 

 

GASOLINE IS FLAMMABLE. NO SMOKING OR OPEN FLAME. 

 

DISCONNECT ALL POWER AND RELIEVE PRESSURE TO THIS EQUIPMENT AND ASSOCIATED SUBMERGED 
PUMP(S) DURING INSTALLATION, SERVICE, OR ANY MAINTENANCE I.E., CHANGING FILTERS. 

WARNING 

ADVERTENCIA 

MISE EN GARDE 

 

You must have training in the installation, service, or maintenance of this equipment (dispenser, pump, site 
master, console, control box, payment terminal, or submerged pump) before working on it. Maintenance repairs 
must be done by authorized personnel only. Warranty work may only be performed by Bennett certified 
technicians. 

 

To prevent electric shock, keep the electrical parts of the Site Master dry. 

 

Electronic components are static sensitive. Use proper static precautions (e.g. static straps) before working on 
the equipment.  

 

The emergency shut-off valve (also called the fire valve, shear valve, or impact valve) must be closed when 
service or maintenance is performed on this equipment. 

 

You must have training in the operation and programming of this Site Master Payment Terminal before using it. 

READ THE OPERATORS MANUAL.

 

 

Make sure this equipment is correctly grounded. Failure to do will cause injury or damage equipment or 
improper operation. Improper grounding voids the warranty. 

 

Do not operate the equipment as a payment terminal unless it is completely assembled. 

CAUTION 

PRECAUCIÓN

 

MISE EN GARDE 

 

Do not drill holes in the Site Master. Holes can cause failure of the electronic equipment. 

THE 

WARRANTY WILL BECOME VOID.

 Use only adhesive backed sign mounting brackets

 

 

IMPORTANT 

IMPORTANTE

 

IMPORTANT 

 

All trained technicians must work in accordance to all requirements, standards, and guidelines specified by the 
suppliers Environmental Standards® Health, Safety, Security & Environment (HSSE) policies. 

Note: 

Bennett Pump 

highly recommends all technicians observe HSSE policies defined by the supplier. Bennett Pump does not impose 
any restrictions or additional requirements contained in Environmental Standards® Health, Safety, Security & 
Environment (HSSE) policies. 

 

 

!! READ AND UNDERSTAND ALL WARNING LABELS ATTACHED TO THE DISPENSER !! 

 

 

Содержание SITE MASTER EMV

Страница 1: ...mation Installation Operation Maintenance Parts Schematics Only Trained Personnel May Work on This Equipment READ THIS MANUAL This manual has important information for safe installation and operation...

Страница 2: ...799 6202 Email sales bennettpump com or salesintl bennettpump com Website www bennettpump com For new manuals visit our web page at www bennettpump com IMPORTANT Examine the shipment immediately upon...

Страница 3: ......

Страница 4: ......

Страница 5: ...al Installation Requirements 7 Site Master SP Footprint 8 Wiring Instructions 9 Determining the Number of Wires Required 9 Point of Sale POS Communication 9 Beginning the Wiring Process 10 Installing...

Страница 6: ...Bennett Site Master Instruction Manual Table of Contents ii Page Intentionally Left Blank...

Страница 7: ...terminal or submerged pump before working on it Maintenance repairs must be done by authorized personnel only Warranty work may only be performed by Bennett certified technicians To prevent electric s...

Страница 8: ...ional Fire Code 2018 Edition UNAUTHORIZED ALTERATION OF BENNETT PRODUCTS DANGER BEFORE PERFORMING ANY TYPE OF SERVICE TO THE DISPENSERS BE SURE TO SHUT OFF ALL ELECTRICAL SUPPLIES AND SECURE THEM IN T...

Страница 9: ...DIMENSIONS Refer to Footprint Diagram 125927 P4208 located inside the Site Master or on the USB provided Site Master Series Maximum 19 25 32 width x 12 depth x 42 height Site Master Series Estimated S...

Страница 10: ...erminal strip and converts the 120VAC into the 12VDC and 24VDC needed for the module to operate The payment module receives power from the Power Supply through the J5 connector on the SBC2 CPU Board a...

Страница 11: ...the unit for conduit connections for the Site Master 2 Anchor the Site Master to the island with four bolts anchor bolts through the base frame Note When anchoring the Site Master always level the uni...

Страница 12: ...A Installation must be in accordance with national electric code NFPA 70 The Automotive and Marine Service Code NFPA 30A and all state and local codes B Use only Underwriters Listed Threaded Rigid Co...

Страница 13: ...Violet RS 485 positive 1 x 18ga Common 1 x 18ga Yellow RS 485 negative RS 485 wires should be twisted together no less than 3 turns per foot to reduce the effects of electrical noise on the communicat...

Страница 14: ...ce panel ground bar Note Use 15 Amp neutral breaking circuit breakers which are supplied by the customer 6 Connect AC Power a Connect the neutral white 14 gauge wire to position 2 of the terminal stri...

Страница 15: ...tallation 3 Pull a Green 12 ga stranded THHN ground wire through the junction box and wiring through and secure at grounding post near the terminal strip in the Site Master s electrical enclosure Term...

Страница 16: ...ATION WIRING DIAGRAM 1 All wiring must be installed and used in accordance with the national electrical code NFPA 70 Automotive and marine service code NFPA 30A state and local electrical codes 2 All...

Страница 17: ...for the other lock 5 To unlock either door turn the key counterclockwise until it stops POWER SWITCH WARNING To prevent electric shock make sure the current is off at the circuit breaker s and the br...

Страница 18: ...on or off When power is applied to the Site Master the Bennett Logo will appear for approximately 3 seconds as shown in Figure 2 3 Note PLEASE PAY INSIDE will be displayed as shown in Figure 2 4 only...

Страница 19: ...tem DC voltages then are sent over to the SBC2 Board through a multi pin conductor from connector J1 of the Power Board to connector J2 on the SBC2 Board The standard glass body fuses are located on a...

Страница 20: ...n of the connections to the terminal strips of all the connections used on the power supply board as shown in Figure 3 3 J1 AC Input A 5 position header is used to receive incoming AC power J2 12 VDC...

Страница 21: ...llow the suggested maintenance frequency and record results in the maintenance log Keep in a readily accessible location CLEANING PAINTED SURFACES 1 Wash the dispenser in a solution of warm water and...

Страница 22: ...Bennett Site Master Instruction Manual Maintenance 18 Page Intentionally Left Blank...

Страница 23: ...visit our web page at www bennettpump com ALL ORDERS MUST INCLUDE THE FOLLOWING INFORMATION Note Many electronic circuit boards have a factory rebuilt equivalent All rebuilt boards have a part number...

Страница 24: ...cuit Board Asm Soft Key 2 7 126972 Display 1 8 132001 Bracket Display CPU Mount 2 9 132008 Bracket Mount SBC 1 10 129313 Circuit Board Assembly SBC2 1 11 113724 Card Reader MAGTEK 1 12 VARIOUS Bracket...

Страница 25: ...a stranded THHN ground wire through the junction box and wiring through and secure at grounding post near the terminal strip in the Site Master s electrical enclosure Terminate the other end at the ma...

Страница 26: ...DIAGRAM 1 All wiring must be installed and used in accordance with the national electrical code NFPA 70 Automotive and marine service code NFPA 30A state and local electrical codes 2 All wiring gauge...

Страница 27: ...Bennett Site Master Instruction Manual Schematics 23 FOOTPRINT...

Страница 28: ...Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Отзывы: