Bennett Site Master Instruction Manual
Schematics
21
SCHEMATICS
FIELD WIRING
Refer to the Wiring Diagrams (126000 – P4229s1 and P4229s2) located inside the Site Master or on the USB provided.
AC POWER CONNECTIONS FOR SITE MASTER SP
Read all safety instructions and notes before applying power to the Site Master.
NOTES FOR POWER WIRING DIAGRAM
5.
All wiring must be installed and used in accordance with the national electrical code
(NFPA #70), Automotive and Marine Service Code NFPA #30), state, and local
electrical codes.
6.
All wiring gauge is minimum required, stranded wire with THHN insulation must be
used. Do not reuse old wire from an existing installation.
7.
Pull a Green 12 ga. stranded THHN ground wire through the junction box and wiring
through and secure at grounding post near the terminal strip in the Site Master’s
electrical enclosure. Terminate the other end at the main electrical service panel
ground bar. Do not terminate at the neutral bar of a sub-panel or rely on metal
conduit for this ground connection. Each Site Master’s grounding post must be
within 1-ohm resistance to earth ground potential. Do not use wire nuts on ground
circuits, use only compression type connectors. This is required to initiate Bennett’s
Limited Warranty.
8.
Use 15 Amp neutral breaking circuit breakers, which are supplied by the customer.
BREAKER IDENTIFICATION:
CB #1 Electronic Power – Hot for electronic power is 115 VAC 50/60 Hz
Note
: No more than 2 Site Master’s per breaker.
ELECTRICAL RATINGS
Electrical Power ……240 WATTS, 115/120V 50/60hz
P4229
Sheet 1
Rev B