25
SECTION 12
MAINTENANCE
MAINTENANCE ITEMS AND MAINTENANCE PERIODS
Bendpak Rotary Screw Compressors require regular
maintenance. Regular maintenance will provide long
Compressor component life and long term trouble free
operation.
1. Bleed off any internal pressure by pulling open
pressure relief valve located on the left side of the Oil
Separation Filter. (See Fig. 12.1 )
2. Confirm the pressure has been bled off by reading
Pressure on oil Separation Tank. (See Fig.12.2 )
MAINTENANCE SCHEDULES
Check the running temperature and working pressure.
(Daily)
Record the current, voltage, temperature and pressure.
(Daily)
Clean compressor only after stopping (Weekly)
Blow the air filter with compressed air. (Weekly
Check oil level (Monthly)
Check the bolts on the belt pulley( Shaft coupling) Only
after compressor is stopped and the power is locked out.)
Blow the cooler with compressed air.
*Please see pages 32 -33 for more detailed information.
ATTENTION:
Reduce the Maintenance intervals in severe operating
environments or severe demand applications.
First 500 operating hours (first Maintenance)
Check the quality of oil. The oil may be reused after
being filtered cleanly. Otherwise, replace it.
Replace the oil filter.
Replace the intake filter.
Replace the oil separation filter.
Check the wear of belt pulley and the alignment of
the motor and Air End pulleys.
Every 2000 Hours
Replace the oil filter.
Replace the intake filter.
Replace the oil separation filter.
Check the wear of belt pulley and the alignment of
the motor and Air End pulleys.
Check intake-control valve.
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS
WITHOUT FIRST ENSURING THAT ELECTRICAL
POWER HAS BEEN DISCONNECTED AT
THE SOURCE OR PANEL AND CANNOT BE
RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS
WITHOUT FIRST ENSURING THAT ALL INTERNAL
PRESSURE HAS BEEN RELIEVED FROM THE
SYSTEM. ISOLATE THE COMPRESSOR FROM
THE AIR SUPPLY LINE /AIR TANK WITH USE
OF SHUT OFF VALVES.
Fig. 12.2
DANGER
SERVICING WHILE
PRESSURIZED CAN
CAUSE SEVERE INJURY.
LOCK OUT SOURCE AND
RELIEVE PRESSURE
BEFORE SERVICING.
Fig. 12.1
Pressure
Relief Valve
Содержание RS7580H603
Страница 34: ...34 Frequent ...
Страница 35: ...35 ...
Страница 36: ...36 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 37: ...37 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 38: ...38 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 40: ...40 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 41: ...41 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 42: ...42 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 43: ...43 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 44: ...44 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 45: ...45 ...
Страница 48: ......