14
Compressor will continue to run in the
STATE: AUTO
UNLOADING
until the system pressure falls below the
preset minimum pressure.
The Compressor maintains the preset system
pressure by moving from the
STATE: AUTO LOADING,
pressuring the system, to the
STATE: AUTO UNLOADING
;
not building any pressure.
Use the monitoring features to monitor pressure, power and
other compressor running values to ensure the Compressor
is operating normally. See The Parameter Section of this
Manual for details on setting pressures and monitoring run-
ning parameters.
The Compressor should run smoothly with no excess
vibrations.
ATTENTION:
Do not restart compressor up within 90 Seconds after
compressor has been stopped. Release all pressure
within AIR OIL separation element before restarting.
Avoid compressor start up when there is back
pressure in the system.
SHUT DOWN PROCEDURE:
1.
Press the
OFF
button, the compressor will move to
STATE: READY STOP
. The Controller will countdown the
Remaining delay until the Compressor will stop and then
shut down the Compressor when the set time is reached.
If the compressor has begun the stop sequence, Press the
Emergency Stop Button if you need to stop the compressor
immediately.
SECTION 10
LCD CONTROLLER PANEL
OPERATION
The LCD CONTROLLER panel is used to monitor and
adjust the Parameters of the Screw Compressor.
The Parameters are set at the factory and it is
recommended to leave most of the settings at their
factory default values.
The values most likely to require adjustment by the end
user are described below.
The Complete Menu Hierarchy is available at the end of
this section.
The Factory Parameters and some of the Customer
Parameters should only be adjusted by a factory trained
service Technician.
LCD CONTROLLER PANEL OVERVIEW
BUTTON DESCRIPTION
START
Start Button; Press this button to
start the Compressor.
STOP
Stop Button: Press this button to
stop the Compressor.
Set Button
: Press this button to confirm the
input data to be saved after modification of
the data.
Down Button:
Press this button to lower
the value during data modification. Press
this button to select a menu option during
menu selection.
DO NOT ASSUME THAT THE COMPRESSOR
CAN NOT STARTUP IF THE MOTOR IS NOT
RUNNING. CONFIRM THE STATE OF THE
COMPRESSOR BEFORE PERFORMING ANY
OPERATION, INSPECTION OR WORK NEAR THE
MOTOR AND ENSURE LOCK OUT AND TAG OUT
PROCEDURES HAVE BEEN PERFORMED.
IN THE EVENT OF ANY TROUBLE OR
OPERATION PROBLEM NOT TERMINATED BY
THE CONTROL SOFTWARE. THE COMPRESSOR
CAN BE SHUT DOWN BY PRESSING
THE EMERGENCY STOP BUTTON.
S
Содержание RS7580H603
Страница 34: ...34 Frequent ...
Страница 35: ...35 ...
Страница 36: ...36 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 37: ...37 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 38: ...38 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 40: ...40 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 41: ...41 RS7580H603 SCREW COMPRESSOR PARTS LIST ...
Страница 42: ...42 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 43: ...43 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 44: ...44 RS7580H603 COMPRESSOR ELECTRIC DIAGRAM ...
Страница 45: ...45 ...
Страница 48: ......