89000004-200
KA 310 STC Installation Manual
Rev 0
6-1
© Honeywell International Inc. Do not copy without express permission of Honeywell.
6
SYSTEM CONFIGURATION
The KA 310 is configured through the setup menu interface on the KI 300.
Figure 6-1 Setup Mode Menu
6.1
KI 300 Setup Mode Entry
Setup mode on the KI 300 is enabled by holding the rotary knob in the pressed state while power is
applied to the unit. Upon successful entry into the setup mode, the KI 300 startup screen is bypassed
and a series of setup menus will become available. Release the rotary knob once the setup mode is
indicated. Pressing the rotary knob will transition to the next set up page. Turning the rotary knob will
change the value on the currently displayed set up page. Each page’s value is internally stored when the
corresponding page is exited.
6.2
Autopilot Configuration
If the KA 310 is connected to an autopilot, the type of autopilot must be configured on the KI 300. In the
setup menu, cycle through the setup pages to the “AP Type” setup page. Turn the rotary knob to select
the correct autopilot interface:
None – This option is selected when the KA 310 is not connected to an autopilot.
Analog – This option is selected when the KA 310 is connected to a BendixKing legacy autopilot
that does not include flight director functionality. Refer to Table 3-5 for the list of BendixKing
legacy autopilot that does not include flight director functionality.
Analog w/FD – This option is selected when the KA 310 is connected to a BendixKing legacy
autopilot that includes flight director functionality. Refer to Table 3-5 for the list of BendixKing
legacy autopilot that includes flight director functionality.
Digital - This option is not applicable for KA 310 installation
REF:
RELEASED FOR THE EXCLUSIVE USE BY: HONEYWELL EMPLOYEE AMERICAS
UP793797