89000004-200
KA 310 STC Installation Manual
Rev 0
Page 2-7
© Honeywell International Inc. Do not copy without express permission of Honeywell.
2.4
Regulatory Compliance
This article meets the minimum performance and quality control standards required by the TSO listed in
the tables below. The KA 310 can only function as a TSO Incomplete article when installed with a KI 300
(PN 89000004-100-00).
Table 2-1: KA 310 TSO Authorization
Function
TSO/SAE/RTCA
Category
Automatic flight guidance and
control systems
TSO-C198 (Incomplete)
DO-325
Class A1, C
2.5
KA 310 Installation Overview
Always follow acceptable avionics installation practices per AC 43.13-1B, AC 43.13-2B, or later FAA
approved revisions of these documents. Follow the installation procedures in Section 4, as it is
presented, to accomplish a successful installation. Read the entire section before beginning the work.
Prior to installation, consider the structural integrity of the KA 310 as defined in Section 3.4. Complete
an electrical load analysis in accordance with the instructions in Section 4.5 on the aircraft prior to
starting the modification to ensure the aircraft electrical system has the ability to source the additional
KA 310 electrical load. Once the installation is complete, perform the post installation checkout
described in Section 7 before closing the work area in case problems occur.
When working with avionics equipment, be aware of the following warnings and cautions.
CAUTION
SERVICE TECHNICIANS MUST OBEY STANDARD SAFETY PRECAUTIONS, SUCH AS WEARING SAFETY
GLASSES, TO PREVENT PERSONAL INJURY WHILE INSTALLING OR PERFORMING SERVICE ON THIS
UNIT.
CAUTION
TURN OFF POWER BEFORE DISCONNECTING WIRING. DISCONNECTING WIRING WITHOUT
TURNING POWER OFF MAY CAUSE VOLTAGE TRANSIENTS THAT CAN DAMAGE THE SYSTEM.
CAUTION
THIS EQUIPMENT INCLUDES ITEMS THAT ARE ELECTROSTATIC DISCHARGE SENSITIVE (ESDS)
DEVICES. ESDS DEVICES ARE SUBJECT TO DAMAGE BY EXCESSIVE LEVELS OF VOLTAGE AND/OR
CURRENT. THE LOW-ENERGY SOURCE THAT MOST COMMONLY DESTROYS ESDS DEVICES IS THE
HUMAN BODY, WHICH, IN CONJUNCTION WITH NONCONDUCTIVE GARMENTS AND FLOOR
COVERINGS, GENERATES AND RETAINS STATIC ELECTRICITY. TO ADEQUATELY PROTECT ESDS
DEVICES, THE DEVICE AND EVERYTHING THAT CONTACTS IT MUST BE BROUGHT TO GROUND
POTENTIAL BY PROVIDING A CONDUCTIVE SURFACE AND DISCHARGE PATHS. USE STANDARD
INDUSTRY PRECAUTIONS TO KEEP RISK OF DAMAGE TO A MINIMUM WHEN TOUCHING,
REMOVING, OR SERVICING THE EQUIPMENT.
REF:
RELEASED FOR THE EXCLUSIVE USE BY: HONEYWELL EMPLOYEE AMERICAS
UP793797