ENG
LI
SH
14
8
8
..
O
Oppeenniinngg tthhee ddrriivvee
Opening the drive housing
After unlocking with the enclosed key, you can
open the door up to an angle of 140°. This gives
you convenient access to the inside of the drive.
99..
G
Geenneerraall ssaaffeettyy iinnssttrruuccttiioonnss ffoorr iinnssttaallllaattiioonn
ATTENTION: Please observe the following notes and instructions for safe instal-
lation.
INCORRECT INSTALLATION CAN LEAD TO SERIOUS INJURIES!
The safe and foreseeable functioning of the door system can only be ensured
by correct installation by a competent person in accordance with the instruc-
tions provided with the product.
According to EN 12635, a competent person is a person who has the appropria-
te training, qualified knowledge and practical experience to correctly and safely
install, check, maintain and repair a door system.
These installation and operating instructions must be read, understood and ob-
served by the person who installs, operates or maintains the operator.
15
When carrying out the installation work, the competent person must comply
with all relevant and applicable regulations on occupational safety and the re-
gulations for the operation of electrical equipment. National occupational sa-
fety regulations, accident prevention regulations and valid standards of the
respective country must be observed and complied with! When installing the
drive, possible hazards in the sense of EN 13241-1 and EN 12453 must be ob-
served.
The guideline "Technical rules for workplaces ASR A1.7" of the committee for
workplaces (ASTA) is valid in Germany for the operator and must be observed
and complied with.
1100..
CChheecckkiinngg tthhee ggaattee // pprreeppaarriinngg tthhee ggaattee ssyysstteem
m
WARNING
Risk of injury due to faults in the door system!
A faulty door system or incorrectly aligned doors can lead to serious injuries
and damage.
SAFETY INSTRUCTION FOR HAZARD AVOIDANCE
Do not use the door system if it needs to be repaired or reset.
Check the entire door system for possible damage and wear before in-
stallation!
Check for corrosion, rust or cracks.
The drive is not designed for the operation of heavy gates. Sluggish doors are
doors that are difficult or impossible to open and close manually. The door run
must not have any incline or decline.
The operator is designed for smooth-running gates that are in a mechanically
fault-free condition and easy to operate by hand (EN 12604). The operator is
suitable for both floor-guided and cantilevered sliding gates.
Check that the door can be opened and closed completely, correctly and
smoothly.
Mechanically secure the door against running out of its guides.
Содержание Premium Slider 500
Страница 34: ...34 TYP Premium Slider 500 500i 800 800i Serien Nr Kaufdatum Händlerstempel und Unterschrift ...
Страница 59: ...E N G L I S H 25 ...
Страница 68: ...34 TYPE Premium Slider 500 500i 800 800i Serial no Date of purchase Retailer s stamp and signature ...
Страница 102: ...34 TYPE Premium Slider 500 500i 800 800i Numéro de série Date d achat Cachet et signature du concessionnaire ...
Страница 136: ...34 TIPO Premium Slider 500 500i 800 800i Número serial Fecha de compra Sello de distribuidor y signatura ...