45
Densité 3+ FR1
User Manual
Status/Name
This contains an expandable tree listing all the alarms reported by this card. Each alarm
name includes an icon that shows its current status
The
Overall alarm
and
GSM contribution
columns contain pulldown lists that allow the
level of contribution of each individual alarm to the alarm named in the column heading to
be set.
Overall Alarm
This column allows configuration of the contribution of each individual alarm to the Overall
Alarm associated with this card. The Overall Alarm is shown in the upper left corner of the
iControl panel, and also appears at the bottom of the Status/Name column.
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM
Alarm Status associated with this card. GSM is a dynamic register of all iControl system
alarms, and is also an alarm provider for external applications. The possible values for this
contribution are related to the Overall alarm contribution:
• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution
can be set to any available value
• If the Overall alarm contribution is selected as any level other than disabled, the GSM
contribution is forced to follow the Overall Alarm.
Levels associated with these alarms:
The pulldown lists may contain some or all of the following options:
Disabled:
The alarm makes no contribution (black icon).
Minor:
The alarm is of minor importance (yellow icon)
Major:
The alarm is of major importance (orange icon)
Critical:
The alarm is of critical importance (red icon)
Passthrough:
The alarm exists but has no effect
(yellow/orange icon, used for text and composite alarms)
Shortcut:
if you click in one of the Set All boxes at the top of a column, you will open a
pulldown that lets you assign a level to all alarms in that column simultaneously.
Once the alarms are configured, you may accept the changes or discard them:
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for
troubleshooting and identifying event sequences. Click in the checkbox to enable logging
of alarm events for each individual alarm.
At the bottom of the window are several other controls:
Copy to other cards
Click this button to open a panel that allows the alarm configuration set for this card to be
copied into another REF-1801 card.
Содержание Miranda DENSITE 3+ FR1
Страница 1: ...User Manual M969 9900 103 2016 11 28 DENSIT 3 FR1 1RU Housing Frame for Densit Modular Products...
Страница 12: ...xii Notices...
Страница 47: ...33 Densit 3 FR1 User Manual Local Control Panel Menu continued...
Страница 48: ...34 CPU ETH2 Controller Card Local Control Panel Menu...
Страница 64: ...50 REF 1801 FR1 Frame Reference Specifications...