42
REF-1801-FR1 Frame Reference
Input tab
To select the reference source for this REF-1801-FR1
Use the pulldown to select the reference source:
•
Auto
– Use the external reference if available; switch to the internal reference if the
external reference is lost or unavailable.
•
External
– use the reference connected to the rear panel
•
Internal
– use the internal reference source
To select the time code source for this REF-1801-FR1
Use the
Timecode Source
pulldown to select the source of timecode that will be inserted in
the outgoing reference signals from this REF-1801-FR1. The choices are:
•
Auto
– Use LTC if available, if not, VITC.
•
VITC
– Extract timecode from the reference input
•
LTC
– Use the timecode connected to the LTC input on the rear panel.
•
OFF
– Do not insert timecode into the output URS signal.
To select the timecode processing mode
Use the
Timecode Processing
pulldown to select how the timecode is processed in the
REF-1801-FR1:
•
Normal
– use the timecode selected by the Timecode Source pulldown as the output
timecode source.
•
Pass through
– pass the timecode selected by the Timecode Source pulldown directly
to the output without internal processing.
The
Pass through mode
is required for correct operation when the time code is not
standard running time code, e.g. when it is counting down. Using this mode will result
in a 1-frame delay in the time code as it passes through the REF-1801-FR1. When pass
through mode is selected, no new input timecode alarms (frame error, phase error) will
be flagged.
The current status of timecode available at the REF-1801-FR1 input is shown in the
LTC
Status
and
VITC Status
areas:
Indication
Meaning
Valid
V
alid time code detected at the input.
Phase error
SMPTE-12 specifies the phase relation between LTC and video. If
the LTC received does not match this alignment window, the card
will flag this error.
Frame error
The time code must match the input reference frame rate. If not,
an error is flagged.
Absent
No time code detected at the input.
Note: The error detection algorithm uses the current reference
format. So, when using internal reference, all information
extracted from the input is out of phase, and the card may flag
errors even if there are none.
Содержание Miranda DENSITE 3+ FR1
Страница 1: ...User Manual M969 9900 103 2016 11 28 DENSIT 3 FR1 1RU Housing Frame for Densit Modular Products...
Страница 12: ...xii Notices...
Страница 47: ...33 Densit 3 FR1 User Manual Local Control Panel Menu continued...
Страница 48: ...34 CPU ETH2 Controller Card Local Control Panel Menu...
Страница 64: ...50 REF 1801 FR1 Frame Reference Specifications...