12
Densité 3+ FR1 Housing Frame
Installing and Replacing the System Card
Installing and Replacing the System Card
The system card is located in the upper right-hand-side of the Densité 3+ FR1 frame, as
seen from the front. The system card is optional, and may be factory-installed when the
system is ordered, or installed by the user later.
At the time of writing, there are two system cards that may be used in the Densité 3+ FR1
frame:
REF-1801-FR1 HD/SD Frame Reference Module
• This version of the REF-1801 card can only be used in the Densité 3+ FR1 frame.
• Its user manual is included as Chapter 4 of this document.
GPI-1501 GPI I/O Module
• The GPI-1501 requires a special rear panel when used with the Densité 3+ FR1 frame.
• See the GPI-1501 User Manual for instructions on installing and using this card and its
associated rear panel.
Note
: As with all Densité cards, you must install the rear panel before inserting the card into
the system card slot.
Specifications
MECHANICAL
Dimensions
1RU x 19” W (485 mm) x 11.25” D (286 mm) with connectors
Weight:
7.16 lbs (3,25 kg) with 1 PSU and controller card installed
POWER
Input Range:
AC 100-240V, 50-60 Hz
Rating:
150 W max each power supply
Operating Temp. Range:
0-40° C
COOLING
Fans:
2 on frame, serviceable
1 on each installed power supply
COMMUNICATION
Connectors:
RJ45 (2)
Compliant to:
Ethernet 10/100 Base-T
ALARM
Connectors:
GPI
Содержание Miranda DENSITE 3+ FR1
Страница 1: ...User Manual M969 9900 103 2016 11 28 DENSIT 3 FR1 1RU Housing Frame for Densit Modular Products...
Страница 12: ...xii Notices...
Страница 47: ...33 Densit 3 FR1 User Manual Local Control Panel Menu continued...
Страница 48: ...34 CPU ETH2 Controller Card Local Control Panel Menu...
Страница 64: ...50 REF 1801 FR1 Frame Reference Specifications...