24
CPU-ETH2 Controller Card
Data Restoration
iControl - click the
Restore Point
button and view the Cards tab.
The tab show a list of the slots
available in the Densité frame, with a
check box, name, and status box for
each.
• The Densité 3+ FR1 frame uses
only slots 1 to 4.
• A GPI-1501 or a REF-1801-FR1
inserted in the dedicated system
card slot will appear in slot 5.
Click the check box to activate the
Data Restore feature for the card in
that slot,
-or-
Click the Select All box at the top to
activate the feature for all slots in the
frame.
Click
Save to controller
at the bottom
to copy all restorable data from the
cards in the selected slots into the
memory on board the CPU-ETH2 controller.
Click
Load to cards
to load the cards in the selected slots with data from the controller’s
memory.
Note that a data restore will only work if the card in the slot is the same type as the card that
was there when the data was saved.
For automatic restore and save:
iControl - click the
Restore Point
button and view the Config tab.
Restore:
The CPU-ETH2 card can be set up to automatically update a card when it is
inserted in a slot previously occupied by a card of the same type whose data was saved.
Thus, a new card can be configured automatically to replace the card that was removed,
saving a lot of time when cards are swapped.
Click the
Default Action
box to enable the auto restore function for all the cards in the frame.
Содержание Miranda DENSITE 3+ FR1
Страница 1: ...User Manual M969 9900 103 2016 11 28 DENSIT 3 FR1 1RU Housing Frame for Densit Modular Products...
Страница 12: ...xii Notices...
Страница 47: ...33 Densit 3 FR1 User Manual Local Control Panel Menu continued...
Страница 48: ...34 CPU ETH2 Controller Card Local Control Panel Menu...
Страница 64: ...50 REF 1801 FR1 Frame Reference Specifications...