Environment
The device may only be operated at the specified surrounding air
temperature (temperature of the surrounding air at a distance of up to
5 cm (1.97 in) from the device) and relative air humidity specified in the
technical data.
Install the device in a location where the climatic threshold values
specified in the technical data will be observed.
Use the device only in an environment within the pollution degree
specified in the technical data.
Relevant for use in Hazardous Locations (Class 1, Division 2):
This equipment is suitable for use in Class 1, Division 2, Groups A, B, C
and D or Non-Hazardous (unclassified) locations only.
When used in Class 1 Division 2 Hazardous Locations, the following
applies:
CLASS I; DIV. 2
GROUPS A; B; C AND D
TEMPERATURE CODE T4
AMBIENT -30 °C ... +70 °C
List of Standards: ISA 12.12.01:2007, CSA C22.2 No. 213-
M1987
This equipmnt must be installed in a tool-locked enclosure when the USB
port will be used.
Warning:
Do not remove or replace while circuit is live unless
the area is known to be free of ignitable concentrations or
flammable substances.