36
MACH 1040
Release 02 03/2013
The following table applies to all device variants:
Applies to software releases previous to 06.0.00:
Applies to software release 06.0.00 and higher:
Applies to software releases previous to 06.0.00:
LED
Display
Color
Activity
Meaning
Stand-
by/Sb
Stand-by
mode
None
Stand-by mode not enabled
Green
Lights up
Standby mode enabled
RM
Ring
Manager
None
The RM function is deactivated.
Green
Lights up
The RM function is active.
The redundant port is disabled.
flashing
Incorrect configuration of the HIPER-Ring
(e.g. the ring is not connected to the ring
port).
Yellow
Lights up
The RM function is active.
The redundant port is enabled.
RM
and
Stand-
by/Sb
ACA
memory
operation
Flashing
alternately
Error in the memory operation
flash
synchronously
– 2 x per period
Save a configuration file from the ACA to the
device.
flash
synchronously
– 1 x per period
Saving a configuration file from the device to
the ACA.
LED
Display
Color Activity
Meaning
FAULT Signal contact 1
Red
Lights up
The signal contact is open, it is
reporting an error.
None
Signal contact is closed, it is not
reporting a detected error.
LED
Display
Color Activity
Meaning
FAULT Signal contact 1
Red
Lights up
The signal contact is open, it is
reporting an error.
None
Signal contact is closed, it is not
reporting a detected error.
Duplicate IP
detection
Red
flashes 4 times a
period
Reports an IP conflict.
LED
Display
Color Activity
Meaning
R1
Signal contact 1
Yellow Lights up
The signal contact is closed in
manual operation.
None
The signal contact is open in
manual operation.
R2
Signal contact 2
Yellow Lights up
The signal contact is closed in
manual operation.
None
The signal contact is open in
manual operation.