MACH 1040
Release 02 03/2013
IEEE C37.90.1
Fast transients (burst)
DC Power Line
± 4 kV
AC Power Line
± 4 kV
Data line
± 4 kV
IEEE C37.90.1
damped oscillation
DC Power Line
± 2,5 kV line/earth; ± 1 kV line/line
AC Power Line
± 2,5 kV line/earth; ± 1 kV line/line
Data line
± 2,5 kV line/earth; ± 1 kV line/line
IEEE C37.90
H.V. Impulse
DC Power Line
± 5 kV line/earth
AC Power Line
± 5 kV line/earth
IEEE C37.90
dielectric strength
DC Power Line, power unit type „L“ 500 V AC
AC Power Line, power unit type
„M“
2000 V AC
DC Power Line, power unit type
„M“
2000 V AC
signal contact type „L“ and „M“
2000 V AC
EMC emitted interference
EN 55022
Class A
FCC 47 CFR Part
15
Class A
German Lloyd
Classifi Construction Guidelines VI-7-3 Part 1 Ed.2001
Environment type
tests, test in comp.
with
Description
Test level
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
Cold
Dry heat
Relative humidity
Vibration, test Fc
Shock, test Ea
-40 °C, 16 hours
+85 °C, 16 hours
95 % (non condensing)
55 °C, 4 cycles
2- 9 Hz with 3 mm amplitude
1 g at 9 - 150 Hz
1.5 g at 200 - 500 Hz
15 g at 11 ms
EMC interference
immunity
IEEE 1613:2009
EMI TYPE tests,
test in comp. with
Description
Test level