8
MACH 1040
Release 02 03/2013
Figure 1: Control Drawing 000154226DNR
For use in Hazardous Locations according ISA12.12.01-2007 Class I Div. 2 Groups A, B, C, D
Control Drawing MACH1040-Family
Hazardous Location
ACA21-USB
Auto
Configuration
Adapter
For maintenance
only – See
Installation
Instructions
V.24
Interface
(External
management)
Data
communication
Ethernet Ports
Power Supply 1
L: 24VDC to 48VDC
M: 100VAC to
240VAC 50/60Hz
Power Supply 2
9: Not present
L: 24VDC to 48VDC
M: 100VAC to
240VAC 50/60Hz
Signal Contacts
(On: O.K.
Open: fault)
Associated
Apparatus:
Equipment with
nonincendive
field wiring
parameters
Ordinary Location - Non-Hazardous Area
The Use in Hazardous Locations is only allowed for MACH1040-Family model No´s which are individually labelled “FOR
USE IN CLASS I, DIVISION 2 HAZARDOUS LOCATIONS”
Notes:
The nonincendive field wiring circuit concept allows interconnection of nonincendive field wiring apparatus and associated
nonincendive field wiring apparatus using any of the wiring methods permitted for unclassified locations when certain
parametric conditions are met.
Capacity: C
a
C
i
+ C
Cable
Inductivity: L
a
L
i
+ L
Cable
The maximum cable length has to be determined as follows:
(a) max. Cable Length < (L
a
- L
i
) / Cable
L
and (b) max. Cable Length < (C
a
- C
i
) / Cable
C
The lower value of (a) and (b) is to apply.
Cable
L
: inductance per unit length of used cable.
Cable
C
: capacitance per unit length of used cable.
Other C-parameters and L-parameters are according to ANSI / ISA 12.12.01 2007 section 7.
Where cable capacitance and inductance values are unavailable, use the following default values: 60pF/foot (200pF/m),
0.2uH/foot (0,7uH/m)
Nonincendive field wiring circuits must be wired in accordance with the National Electrical Code (NEC), NFPA 70 , article
501.
Vmax Imax
Ci
Li
The Relay Terminals are dependent upon the following Entity
Parameters:
30V 90mA 50pF
2µH
The MACH1040-Family is an open type which must be installed within an enclosure appropriate for
environmental protection.
WARNING - Explosion Hazard – Do not disconnect Equipment while the circuit is live or unless the area
is known to be free of ignitable concentrations.
WARNING – Explosion Hazard – Substitution of any component may impair suitability for Class I,
Division 2.
Do not open when energized.
CONTROL DRAWING for Full Gigabit Ethernet Switch
MACH1040 Family
according to ANSI / ISA-12.12.01 – 2007
Rev.: 2
Date: 2011-03-18
Document No.: 000154226DNR
Page 1 of 1