Installation EAGLE20/30

Release 11 09/2020

Technical support

https://hirschmann-support.belden.com

User Manual

Installation
Industrial Security Router
EAGLE20/30

Содержание Hirschmann EAGLE20

Страница 1: ...Installation EAGLE20 30 Release 11 09 2020 Technical support https hirschmann support belden com User Manual Installation Industrial Security Router EAGLE20 30...

Страница 2: ...he performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to...

Страница 3: ...100 Mbit s twisted pair port 21 1 5 2 100 1000 Mbit s F O port optional 21 1 5 3 100 1000 Mbit s twisted pair port optional 22 1 5 4 Pin assignments 22 1 6 WAN port optional 23 1 7 Display elements 2...

Страница 4: ...ly voltage with the characteristic value CC 36 2 5 4 Signal contact 36 2 6 Operating the device 37 2 7 Connecting data cables 37 2 7 1 Twisted Pair ports 37 2 7 2 100 1000 Mbit s F O port optional 38...

Страница 5: ...es described in the Hirschmann product information including this manual Operate the product only according to the technical specifications See Technical data on page 44 Connect to the product only co...

Страница 6: ...relieves in such a way that they prevent any mechanical damage to cables wires or conductors caused by external influences or their own weight To prevent damage to device connections connectors and ca...

Страница 7: ...ements listed are complied with All of the following requirements are complied with The electrical wires are voltage free The cables used are permitted for the temperature range of the application cas...

Страница 8: ...r supply complies with the requirements for a safety extra low voltage SELV as per IEC EN 60950 1 A fuse suitable for DC voltage is located in the plus conductor of the power supply The minus conducto...

Страница 9: ...G EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENT MAY I...

Страница 10: ...de of the type designation on the device Relay contacts Equipment with non incendive field wiring parameters Polarity is not relevant The relay terminals are dependent upon the following entity parame...

Страница 11: ...Code NEC NFPA 70 article 501 The earth conductor must be at least the same wire size mm or AWG as the supply conductors WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY F...

Страница 12: ...cations system is illegal The SHDSL port is used exclusively for direct data connections between SHDSL enabled devices Warning This is a class A device This device can cause interference in living are...

Страница 13: ...d operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Страница 14: ...l HiVision Network Management software provides you with additional options for smooth configuration and monitoring ActiveX control for SCADA integration Auto topology discovery Browser interface Clie...

Страница 15: ...low you to set up switched and routed industrial Ethernet networks that conform to the IEEE 802 3 standard The devices work without a fan The device is mounted by latching in place on a DIN rail There...

Страница 16: ...uter with gigabit ports 8 hyphen 9 10 Number Fast Ethernet ports 04 4 11 12 Number Gigabit Ethernet ports 00 0 02 2 13 15 Configuration of the uplink ports 2O6 2 SFP slot 999 Not present 16 17 Configu...

Страница 17: ...ifications Note You will find detailed information on the certificates and declarations applying to your device in a separate overview See table 5 on page 18 Item Product characteristic Characteristic...

Страница 18: ...X X X X X X X X X UL 508 X X X X X X X X X X X EN 60950 1 X X X X X X X X X X X X X X X EN 61131 2 X X X X X X X X X X X X X X X FCC X X X X X X X X X X X X X X X UL 60950 1 X X X X X X X X X Oil and...

Страница 19: ...acteristic value K9 1 voltage input 3 pin terminal block Supply voltage with the characteristic value KK 2 voltage inputs for redundant power supply 3 pin terminal block 10 Connection for the signal c...

Страница 20: ...4 2 Supply voltage with the characteristic value KK For the redundant power supply of the device two 3 pin terminal blocks are available For further information see Supply voltage with the characteris...

Страница 21: ...nents according to the IEEE 802 3 10BASE T 100BASE TX standard This port supports Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half duplex mode 100 Mbit s full...

Страница 22: ...components according to the IEEE 802 3 100BASE FX 1000BASE SX 1000BASE LX standard This port supports Autonegotiation Full duplex mode 1 5 4 Pin assignments RJ45 Pin 10 100 Mbit s 1000 Mbit s PoE MDI...

Страница 23: ...Aggregation of 2 links within the same port SHDSL Single Pair High Bit Rate Digital Subscriber Line M12 4 pin D coded Pin Data PoE 1 TX Positive VPSE 2 RX Negative VPSE 3 TX Positive VPSE 4 RX Negati...

Страница 24: ...Status None Device starts Device is not ready for operation Green Lights up Device is ready for operation Characteristics can be configured Red Lights up The device reports a detected error See Refere...

Страница 25: ...on the software release Software support for the function is unimplemented at the time of publishing this manual Display Color Activity Meaning Link status None Device detects an invalid or missing li...

Страница 26: ...obally disabled 2 The configured VRRP instances have not met the preconditions for operation Green Lights up At least 1 VRRP instance is in Master mode Yellow Lights up No VRRP instances are in Master...

Страница 27: ...device The V 24 interface is electrically insulated from the supply voltage Figure 1 Pin assignment of the V 24 interface and the DE9 connector The terminal cable is available as an accessory See Acce...

Страница 28: ...is used for saving loading the configuration data and diagnostic information and for loading the software The USB interface has the following properties Supports the USB master mode Supports USB 2 0...

Страница 29: ...ontact indicates the device status It can be configured using the device management 1 9 2 Digital input optional Note Only for supply voltage with the following characteristic values CC K9 The support...

Страница 30: ...nstalling an SFP transceiver optional Connecting the terminal blocks Operating the device Connecting data cables Filling out the inscription label 2 1 Checking the package contents Check whether the p...

Страница 31: ...s Slide the upper snap in guide of the device into the DIN rail Press the media module downwards onto the clip in bar Snap in the device WARNING FIRE HAZARD Install the device in a fire enclosure acco...

Страница 32: ...aturing supply voltage with the characteristic value K9 or KK have a connection for protective grounding The device variants featuring supply voltage with the characteristic value CC and not featuring...

Страница 33: ...chmann SFP transceivers See Accessories on page 54 Figure 5 Installing SFP transceivers Installation sequence Proceed as follows Take the SFP transceiver out of the transport packaging 1 Remove the pr...

Страница 34: ...fore connecting the electrical wires always verify that the requirements listed are complied with See Requirements for connecting electrical wires on page 7 Failure to follow these instructions can re...

Страница 35: ...d perform the following steps Remove the power connector from the device Connect the wires according to the pin assignment on the device with the clamps Fasten the wires connected by tightening the te...

Страница 36: ...power failure You can avoid this message by changing the configuration in the management or with power supply units of the same type by feeding the supply voltage in through both inputs 2 5 4 Signal...

Страница 37: ...s provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run p...

Страница 38: ...on page 21 2 7 3 WAN port optional Note In general you should adhere to the following recommendations for data cable connections in environments with high electrical interference levels Provide coppe...

Страница 39: ...addresses Input via the V 24 interface Input via the HiView or Industrial HiVision application You find further information about the applications HiView or Industrial HiVision on the Internet at the...

Страница 40: ...ou to type in a new password Type in your new password To help increase security choose a password that contains at least 8 characters which includes upper case characters lower case characters numeri...

Страница 41: ...68 F 20 C higher than the ambient temperature This depends on the configuration of your device 5 Maintenance and service When designing this device Hirschmann largely avoided using high wear parts The...

Страница 42: ...nal blocks Disconnect the grounding To remove the device from the DIN rail press the device downwards and pull it out from under the DIN rail Figure 9 Removal from the DIN rail WARNING ELECTRIC SHOCK...

Страница 43: ...er optional Figure 10 De installing SFP transceivers De installation sequence Proceed as follows Open the locking mechanism of the SFP transceiver 1 Pull the SFP transceiver out of the slot via the op...

Страница 44: ...replaceable fuse Back up fuse Nominal rating Characteristic 6 3 A slow blow Peak inrush current 4 A Power supply Supply voltage with the characteristic value K9 and KK See Requirements for connecting...

Страница 45: ...40 F 185 F 40 C 85 C Humidity 10 95 non condensing Air pressure minimum 700 hPa 9842 ft 3000 m maximum 1060 hPa 1312 ft 400 m FAULT signal contact Switching current max 1 A SELV Switching voltage max...

Страница 46: ...NorthAmerica Annex_A 32 TCPAM 2800 9186 3 2048 4096 13 5 NorthAmerica Annex A 16 TCPAM 3300 10827 4 1024 2048 13 5 NorthAmerica Annex A 16 TCPAM 4500 14764 5 704 1408 13 5 NorthAmerica Annex A 16 TCP...

Страница 47: ...r the characteristic value see Device name and product code on page 16 Figure 12 Dimensions of the device variants without WAN ports with operating characteristic value E and T For the characteristic...

Страница 48: ...name and product code on page 16 Figure 14 Dimensions of the device variants with WAN ports with operating characteristic value E and T For the characteristic value see Device name and product code on...

Страница 49: ...032 AC and DC supply connections Class A Class A GL Guidelines AC and DC supply connections EMC 1 FCC 47 CFR Part 15 AC and DC supply connections Class A Class A EN 61000 6 4 AC and DC supply connecti...

Страница 50: ...nnection EN 61000 4 5 IEEE 1613 line ground 2 kV 1 kV 2 kV 5 kV EN 61000 4 5 line line 1 kV 0 5 kV 1 kV 1 kV Voltage surges AC supply connection EN 61000 4 5 IEEE 1613 line ground 2 kV 1 kV 2 kV 5 kV...

Страница 51: ...300 A m Stability Standard applications Navy applications Railway applications Substation applications IEC 60068 2 6 test Fc Vibration 5 Hz 8 4 Hz with 0 14 in 3 5 mm amplitude 2 Hz 13 2 Hz with 0 04...

Страница 52: ...dB km 800 MHz km LX LC MM 1310 nm c 62 5 125 m 0 10 5 dB 0 550 m 1 0 dB km 500 MHz km LX LC SM 1310 nm 9 125 m 0 10 5 dB 0 20 kmd d Including 2 5 dB system reserve when compliance with the fiber data...

Страница 53: ...km MM LC MM 1310 nm 62 5 125 m 0 11 dB 0 4 km 1 0 dB km 500 MHz km SM LC SM 1310 nm 9 125 m 0 13 dB 0 25 km 0 4 dB km 3 5 ps nm km SM LC SM 1310 nm 9 125 m 10 29 dB 25 65 km 0 4 dB km 3 5 ps nm km LH...

Страница 54: ...ue K9 2 3 pin terminal block for the supply voltage only for device variants featuring supply voltage with characteristic value KK 2 2 pin terminal block for the supply voltage only for device variant...

Страница 55: ...tiation mode including autocrossing M SFP SX LC 943 014 001 M SFP SX LC EEC 943 896 001 M SFP MX LC EEC 942 108 001 M SFP LX LC 943 015 001 M SFP LX LC EEC 943 897 001 M SFP LX LC 942 023 001 M SFP LX...

Страница 56: ...nk loss detection times compared to twisted pair ports provided by the device directly Not applicable for combo ports Not applicable for ports which support only Gigabit Ethernet To set autocrossing m...

Страница 57: ...c compatibility of multimedia equipment Emission Requirements EN 60950 1 Information technology equipment Safety Part 1 General requirements EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Gen...

Страница 58: ...Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through netw...

Страница 59: ...Installation EAGLE20 30 Release 11 09 2020 59...

Страница 60: ......

Отзывы: