If there are more than one multiviewer in the same network environment, it is
important to assign each a unique system name, so that you can tell them apart (for
example, when using a remote control panel such as the Kaleido-RCP2 or RCP-200).
4 Under
Ethernet
, type the appropriate IP addresses, network masks, and gateway
settings, and review the detected connection speeds and duplex modes for your
Kaleido-IP’s network adapters.
Note:
The system name must comply with RFC 1123, because it is also used
as the device’s host name. Up to 8 characters are allowed, limited to A-Z, a-z,
0-9, and the hyphen character. The system name cannot start or end with a
hyphen character.
LAN1 (management
port) IP address
Set the network IP address to be used for multiviewer management:
that is, any PC that uses XEdit or XAdmin to configure this
multiviewer and any Kaleido-RCP2 / RCP-200 must have IP
connectivity to the
LAN1
port. See also
LAN2 or higher
(media port)
Set the network IP addresss to be used for the
Media Network
. This
port must have IP connectivity to the associated streaming devices
(e.g. encoders, multiplexers). See also
To omit network configuration for an unused Media Port, clear the
corresponding
Enabled
check box.
Network mask
Set the connected network’s subnet mask.
Default gateway
If your
Management Network
is not configured with a gateway,
clear the default gateway IP address, by clicking
Remove
.
Gateway
If
LAN1
,
LAN2
, or higher are configured within different subnets,
and this multiviewer is meant to monitor HLS, RTSP, or RTMP
sources, then add the required gateway addresses by clicking
Add
,
and then typing the appropriate gateway address, for each LAN
section.
Detected link mode By default, all network ports are set to auto-negotiate. The
connection speed and duplex mode will be set automatically based
on the corresponding port settings on the associated switch.
Configured link
mode
10000 Mbps full-duplex
communication can only be achieved via
auto-negotiation, as required by the IEEE-802.3 standard, section
28D.5. Should your network configuration require specific speed
and duplex mode settings, select the appropriate value from the
Configured link mode
list.
Содержание grass valley Kaleido-IP X120
Страница 14: ...14 Table of Contents...
Страница 17: ...17 Kaleido IP X320 X120 Installation Service Manual Overview of the Kaleido IP System...
Страница 18: ...18 Overview Overview of the Kaleido IP System...
Страница 26: ...26 Multiviewer Cabling Changing the Output Resolution...
Страница 99: ...99 Kaleido IP X320 X120 Installation Service Manual For more information about recycling contact Grass Valley...
Страница 100: ...100 Maintenance Troubleshooting Disposal and Recycling Information...
Страница 109: ...109 Kaleido IP X320 X120 Installation Service Manual...