29
Densité 3+ FR4
User Manual
The alarm status list may contain some or all of the following options:
Alarm status
Significance
The alarm makes no contribution (black icon)
The alarm is of minor importance (yellow icon)
The alarm is of major importance (orange icon)
The alarm is of critical importance (red icon)
The alarm exists but has no effect (used for text and composite alarms)
Shortcut:
if you click on “Set All” at the top of one of these columns, you will open a pulldown
list that lets you assign a level to all alarms in that column simultaneously.
Once the alarms are configured, you may accept the changes or discard them:
Log Events
iControl maintains a log of alarm events associated with the card. The log is useful for trouble-
shooting and identifying event sequences. Click in the checkbox to enable logging of alarm
events for each individual alarm.
At the bottom of the window are several other controls:
Copy to other cards
Click this button to open a panel that
allows the alarm configuration set for
this card to be copied into other CPU-
ETH3 controllers in other frames.
Select one or more destination
controllers from the list in the window
by clicking in the checkboxes, or all of
them by clicking in the
All
checkbox