Operating Instructions Automatic Single-Head Serging Machine 1265-4
Beisler GmbH
B-11
B.2
Functions of the machine
B.2.8 Switches
Power switch / Emergency stop switch, Fig. 11:
Main switch / Emergency stop switch
The main switch
2
is used to switch the power supply of the machi-
ne on or off. In case of extended production intermissions, the machi-
ne must be switched off with the main switch so that all functional units
are disabled. The main switch is also used as an emergency stop switch.
The main switch is located at the machine frame below the sewing head.
On / off switch for the bonding station heating module
The heating module
1
of the optional bonding sta-
tion has a thermostat with a separate on / off switch
that is installed below the bonding station.
Program stop switch
When the program stop switch
3
is pressed, all
machine movements and the sewing process are in-
terrupted immediately.
The switch is locked after it has been pressed. When
rotated clockwise, the switch is unlocked and returns
to its original position. The control performs a reset.
NOTE - Program stop switch
When the program stop switch is actuated, it merely can-
cels the machine cycle while the program control and
the machine drive continue to be supplied with electric
voltage. To interrupt the power supply, switch the ma-
chine off using the main switch.
Fig. 11