Service Instructions Automatic Single-Head Serging Machine 1265-4
Beisler GmbH
C-26
C.6
Troubleshooting
Error message
Cause
Correction
Photocells not bright: 13;
15; 16
Photocell does not respond to light
change
Adjust photocell properly; reflective
surface dull, clean as necessary;
replace photocell
I/O communication error
Error during data transmission between
control and I/O module
Check all cable connections (flat ribbon
cables) to 9020013 /. 9020024; if
required, replace contol module 9020013
or module 9020024
ES 02
Photocell 15 missing
Connect photocell 15,
remove link at X24-Pin2
Thread breakage at sewing
head
Sewing machine thread monitor has
responded
Pass thread through needle
Error 45-49:
I/O RES
Internal hardware error during data
transmission
Replace adapter PCB 9020013 –
9020020