GT-650/GT-900 User's Manual
63
Notes!
EDIT LOCATION submenu is available after pressing the “EDIT”
menu key and SELECT LOCATION submenu is available after
pressing the “SEL” menu key afterwards. As long no location is
entered at all, "SEL" menu is not offered.
Only locations under selected client code in MENU / CLIENT menu
are selectable when “SEL” menu key is pressed. Only locations
under selected client code are displayed when entering the location
root after pressing the “EDIT” menu key. As long no location is
entered at all, "SEL" menu is not offered.
INT ............. Interval (validity of test certificate), fixed parameter i.e. 12 months
(it can be edited by “es control” software only).
Also due date is displayed i.e. date of expiring the certificate
validity. The DUE date will be recalculated on the date of saving the
test result of the DUT.
CLI ............. Client name (it can be edited by “es control” software only)
SIT ............. Site name (it can be edited by “es control” software only)
TYP ........... Appliance type or AUTO-TEST name. It will be offered on bases of
already selected TC# (AUTO-TEST code) and cannot be changed in this
menu.
MAN .......... Manufacturer of the appliance (it can be edited by “es control”
software
only)
SN# ............ Serial Number of the appliance (it can be edited by “es control”
software
only)
REM ........... Remarks (it can be edited by “es control” software only) (750
characters max.)
Notes!
If the appliance code was selected among the ones already entered in GT-
650/GT-900 tester, then all belonging entered attributes will be offered too. If
the appliance code was newly created, then all attributes except INT (Interval)
and CL# (client code) will be empty. Default offered INT value is 12 months and
can be changed by “es control” software only. CL# (client code) will be offered
on bases of selected CL# in MENU / CLUENT menu. If none of CL#s is selected,
then CL# line will be empty.
Mandatory fields are only AP# (appliance code) and TC# (AUTO-TEST), all other
attributes are not mandatory.
STEP 3
Carry out the measurements
Next description is valid for STANDARD AUTO-TEST mode only, FAST mode
description see in section “AUTO-TEST modes” on page 59.
Once all wished attributes are entered/edited, press the START key, the following
display will appear: