GT-650/GT-900 User's Manual
53
AUTO-TEST MODE (GT-900 only)
This is most common used test mode as it leads the operator through the whole
test procedure. There are 18 factory-programmed AUTO-TESTS for NON UK region
and 16 AUTO-TESTS for UK region and free space for additional 50 customer-
created ones.
Factory-programmed AUTO-TESTS for PC I appliances (NON UK REGION)
(listed figures present limit values in each test)
Tests
(TC#)
145 146 147 148
AUTO-TEST description
Standard
appliance PC I,
mains cord
max. 5m, R
PE
test current low
(200mA)
Standard
appliance PC
I, mains cord
max. 5m, R
PE
test current
high (5A)
Appliance PC I
with heating
elements,
mains cord
max. 5m,
substitute
leakage test
IT appliance
PC I, mains
cord max. 5m,
no insulation
test, earth
leakage test
AUTO-TEST name
(default)
APP. 200MA
PC I
APP. 5A
PC I
HEATING
PC I
IT
PC I
Visual
Inspection
Yes Yes Yes Yes
Protective earth bond
resistance 200 mA (
)
0.30 - 0.30
0.30
Protective earth bond
resistance 5 A (
)
- 0.3 - -
Insulation resistance
500 V (M
)
1.00 1.00 0.30 -
Insulation resistance
250 V (M
)
- - - -
Substitute leakage
current (mA)
- -
3.50
-
Earth leakage current
with differential
method (mA)
3.50 3.50 - 3.50
Touch leakage current
(mA)
- - - -
Apparent power (kVA)
3.7
3.7
-
3.7