Electrical installation
Version: 2.2
───
89
XTS
8.5.1
Parallel connection of the
modules
Single-channel contactor switch-off
The figure below shows a wiring example of a single-channel con-
tactor switch-off for a maximum of two modules:
24 V
DC
power supply unit
48 V
DC
power supply unit
Puls power supply
unit
QS20.241 / QT20.241
QS40.481 / QT40.481
Primary fusing
See documentation on Puls website
See documentation on Puls website
Secondary fusing
2-pin 4 A circuit breaker
5SL4204-6
Outlet to module with supply
16 A "B" circuit breaker, Siemens 5SY6116-6
Outlet to brake chopper terminal
4 A "C" circuit breaker, Siemens 5SY6104-7
Single-channel contactor switch-off
Siemens 3RT2526-2BB40 + 3RT2926-1BB00
Self-locking of the movers based on the arma-
ture short-circuit principle
Modules have no "Safe Torque Off" STO and
no "Safe Limited Speed" SLS function