![Beckhoff EP3204 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/beckhoff/ep3204/ep3204_documentation_2719256040.webp)
Commissioning/Configuration
EP3204 and EP3314
40
Version: 2.2
6.2.4
Summary
Summary of the calculation rules:
With the values:
Index in the CoE directory with
n: channel number with 0 ≤ n ≤ 3 (channel 1 - 4)
X
1
: Raw value of the 1
st
measurement
0x80nE:01
X
2
: Raw value of the 2
nd
measurement
0x80nE:03
PT100
PT1000
2-wire
4-wire
2-wire
4-wire
Gv: Vendor Gain
0x80nF:04
0x80nF:06
0x80nF:0A
0x80nF:0C
Ov: Vendor Offset
0x80nF:03
0x80nF:05
0x80nF:09
0x80nF:0B
3-wire
Gv
1
: Vendor gain, 1
st
measurement
0x80nF:04
0x80nF:0A
Ov
1
: Vendor offset, 1
st
measurement
0x80nF:03
0x80nF:09
Gv
2
: Vendor gain, 2
nd
measurement
0x80nF:02
0x80nF:08
Ov
2
: Vendor offset, 2
nd
measurement
0x80nF:01
0x80nF:07
G
U
: User Gain
0x80n0:18
O
U
: User Scale Offset
0x80n0:17
G
S
: User Scale Gain
0x80n0:12
O
S
: User Scale Offset
0x80n0:11
ƒ
lin
:
Function for mapping to the selected
method of representation
ƒ
pres
: Linearization function
Y
R1
: Output value in 1/256 Ω
0x80nE:02
Y
R2
: Output value in 1/256 Ω
0x80nE:04
Y: Output value PDO
Overflow Y
R1
and Y
R2
after 16 bits
These values are only for fault finding. The registers overflow after 16 bits, i.e. at 65536.
Содержание EP3204
Страница 2: ......