Object description and parameterization
EL72x1-901x
196
Version: 1.9
Index 6001 FB Touch probe inputs
Index (hex) Name
Meaning
Data type
Flags
Default
6001:0
FB Touch probe inputs Maximum subindex
UINT8
RO
0x14 (20
dec
)
6001:01
TP1 Enable
Touchprobe 1 switched on
BOOLEAN
RO
0x00 (0
dec
)
6001:02
TP1 pos value stored
Positive value of Touchprobe 1 saved
BOOLEAN
RO
0x00 (0
dec
)
6001:03
TP1 Neg value stored
Negative value of Touchprobe 1 saved
BOOLEAN
RO
0x00 (0
dec
)
6001:09
TP2 Enable
Touchprobe 2 switched on
BOOLEAN
RO
0x00 (0
dec
)
6001:0A
TP2 pos value stored
Positive value of Touchprobe 2 saved
BOOLEAN
RO
0x00 (0
dec
)
6001:0B
TP2 neg value stored
Negative value of Touchprobe 2 saved
BOOLEAN
RO
0x00 (0
dec
)
6001:11
TP1 pos position
Positive value of Touchprobe 1
Unit
: the given value must be multiplied by the corre-
UINT32
RO
0x00000000
(0
dec
)
6001:12
TP1 neg position
Negative value of Touchprobe 1
Unit
: the given value must be multiplied by the corre-
UINT32
RO
0x00000000
(0
dec
)
6001:13
TP2 pos position
Positive value of Touchprobe 2
Unit
: the given value must be multiplied by the corre-
UINT32
RO
0x00000000
(0
dec
)
6001:14
TP2 neg position
Negative value of Touchprobe 2
Unit
: the given value must be multiplied by the corre-
UINT32
RO
0x00000000
(0
dec
)
Index 6010 DRV Inputs
Index (hex) Name
Meaning
Data type
Flags
Default
6010:0
DRV Inputs
Maximum subindex
UINT8
RO
0x13 (19
dec
)
6010:01
Statusword
Statusword
Bit 0: Ready to switch on
Bit 1: Switched on
Bit 2: Operation enabled
Bit 3: Fault
Bit 4: reserved
Bit 5: Quick stop (inverse)
Bit 6: Switch on disabled
Bit 7: Warning
Bit 8 + 9: reserved
Bit 10: TxPDOToggle (selection/deselection via
Bit 11: Internal limit active
Bit 12: (Target value ignored)
Bit 13 - 15: reserved
UINT16
RO
0x0000 (0
dec
)
6010:03
Modes of operation
display
Modes of operation display.
Permitted values:
9: Cyclic synchronous velocity mode (CSV)
10: Cyclic synchronous torque mode (CST)
11: Cyclic synchronous torque mode with commutation
angle (CSTCA)
UINT8
RO
0x00 (0
dec
)
6010:06
Following error actual
value
Following error
Unit
: the given value must be multiplied by the corre-
INT32
RO
0x00000000
(0
dec
)
6010:07
Velocity actual value
Display of the current velocity value
Unit:
see Index
INT32
RO
0x00000000
(0
dec
)
6010:08
Torque actual value
Display of current torque value
The value is specified in 1000th of the
rated current
(0x8011:12)
= 0 :
M = ((Torque actual value / 1000) x (rated current /
√2)) x torque constant (
)
= 1 :
M = ((Torque actual value / 1000) x rated current)) x
torque constant (
)
INT16
RO
0x0000 (0
dec
)
6010:12
Info data 1
Synchronous information (selection via subindex
)
UINT16
RO
0x0000 (0
dec
)
6010:13
Info data 2
Synchronous information (selection via subindex
UINT16
RO
0x0000 (0
dec
)
Содержание EL72 1-901 Series
Страница 1: ...Documentation EL72x1 901x Servo Motor Terminals with OCT and STO 50 V DC 1 9 2020 02 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Страница 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Страница 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Страница 86: ...Commissioning EL72x1 901x 86 Version 1 9 Fig 88 Incorrect driver settings for the Ethernet port...
Страница 140: ...Commissioning EL72x1 901x 140 Version 1 9 0hex 80hex Fault reset 6hex Shutdown 7hex Switch on Fhex Enable operation...
Страница 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Страница 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Страница 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Страница 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...