Integrated safety
EL72x1-901x
180
Version: 1.9
6.2.4
Application example for STO function (Cat. 3, PL d)
Application example (STO – Safe Torque Off)
The following application example shows how the EL72x1-9014 can be wired together with an EL2904 in
order to implement an STO function according to EN 61800-5-2.
The user must realize an appropriate evaluation for the wiring between the safety output terminal (EL2904)
and the servo terminal (EL72x1-9014), so that a fault exclusion is permissible for external supply and cross-
circuit in this wiring.
Components involved
• Emergency stop device (control switch S1) according to ISO 13850 and control switch S2
• 1 safety input terminal (EL1904) and 1 input terminal (EL 1004)
• 1 safety output terminal (EL2904)
• 1 safety logic terminal (EL6900) with function block "ESTOP"
• 1 servo terminal (EL72x1-9014) with STO input
• Programmable logic controller (PLC) and EtherCAT fieldbus
A safety door (S1 and S2) and a restart signal (S3) are logically linked on an ESTOP function block. The
EStopOut signal is transferred to the NC controller, with which, for example, the Enable signal of the
EL72x1-9014 can be switched. The STO input of the EL72x1-9014 is operated via the delayed output
EStopDelOut. The EL72x1-9014 supplies the information that the STO function is active via the standard
controller. This information is transferred to the EDM input of the ESTOP function block and additionally to
the EDM function block in order to generate an expectation for this signal.
Содержание EL72 1-901 Series
Страница 1: ...Documentation EL72x1 901x Servo Motor Terminals with OCT and STO 50 V DC 1 9 2020 02 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Страница 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Страница 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Страница 86: ...Commissioning EL72x1 901x 86 Version 1 9 Fig 88 Incorrect driver settings for the Ethernet port...
Страница 140: ...Commissioning EL72x1 901x 140 Version 1 9 0hex 80hex Fault reset 6hex Shutdown 7hex Switch on Fhex Enable operation...
Страница 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Страница 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Страница 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Страница 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...