Object description and parameterization
EL72x1-901x
224
Version: 1.9
Index 2040 Amplifier Info data
Index (hex) Name
Meaning
Data type
Flags
Default
2040:0
Amplifier Info data
Maximum subindex
UINT8
RO
0x12 (18
dec
)
2040:11
Amplifier temperature
Internal terminal temperature
Unit
: 0.1 °C
UINT16
RO
0x0000 (0
dec
)
2040:12
DC link voltage
DC link voltage
Unit
: mV
UINT32
RO
0x00000000
(0
dec
)
Index 2041 Info data
Index (hex) Name
Meaning
Data type
Flags
Default
2041:0
Info data
Maximum subindex
UINT8
RO
0x11 (17
dec
)
2041:11
Auxiliary voltage (10
V)
Auxiliary voltage
Unit
: mV
UINT32
RO
0x00000000
(0
dec
)
Index 2058 OCT Info data
(these data are always read in automatically from the electronic type plate of the motor and serve purely
informative purposes)
Index (hex) Name
Meaning
Data type
Flags
Default
2058:0
OCT Info data
Maximum subindex
UINT8
RO
0x1F (31
dec
)
2058:11
Encoder Type
Feedback type
2: rotary encoder, unipolar counting
UINT16
RO
0x0000 (0
dec
)
2058:12
Resolution
Resolution of the feedback
Unit
: Steps per revolution
UINT32
RO
0x00000000
(0
dec
)
2058:13
Range
Working range of the feedback. On leaving this range
there is an overflow of the position.
Unit
: Revolutions
UINT32
RO
0x00000000
(0
dec
)
2058:14
Type Code Name
Name of the feedback
STRING
RO
2058:15
Serial No
Serial number of the feedback
STRING
RO
2058:16
Firmware Revision No Revision of the firmware
STRING
RO
2058:17
Firmware Date
Date of the firmware
STRING
RO
2058:18
EEPROM Size
EEPROM size
UINT16
RO
0x0000 (0
dec
)
2058:19
Temperature
Temperature
Unit
: 0.1°
INT16
RO
0x0000 (0
dec
)
2058:1A
LED Current
Current of the feedback LED
Unit
: 0.1 mA
UINT16
RO
0x0000 (0
dec
)
2058:1B
Supply voltage
Supply voltage of the feedback
Unit
: mV
UINT32
RO
0x00000000
(0
dec
)
2058:1C
Life- time
Operating hour counter
Unit
: Minutes
UINT32
RO
0x00000000
(0
dec
)
2058:1D
Received Signal
Strength Indicator
Received signal strength at the terminal
Unit
: %
UINT16
RO
0x0000 (0
dec
)
2058:1E
Slave Received Signal
Strength Indicator
Received signal strength at the encoder
Unit
: %
UINT16
RO
0x0000 (0
dec
)
2058:1F
Line delay
Running time of the signal in the cable
Unit
: ns
UINT16
RO
0x0000 (0
dec
)
Index 2059 OCT Nameplate
The parameters described in this index are always read from the electronic type plate of the connected
motor. These parameters automatically lead to the parameters marked with an asterisk (*) in this chapter, if
automatic scanning of the electronic type plate is switched on (index
Содержание EL72 1-901 Series
Страница 1: ...Documentation EL72x1 901x Servo Motor Terminals with OCT and STO 50 V DC 1 9 2020 02 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Страница 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Страница 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Страница 86: ...Commissioning EL72x1 901x 86 Version 1 9 Fig 88 Incorrect driver settings for the Ethernet port...
Страница 140: ...Commissioning EL72x1 901x 140 Version 1 9 0hex 80hex Fault reset 6hex Shutdown 7hex Switch on Fhex Enable operation...
Страница 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Страница 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Страница 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Страница 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...