Error handling and diagnostics
CXxxxx-M510/B510
76
Version: 1.0
6.4
PDOs
SendCounter
TxPDOs feature an additional SendCounter variable under the
Control
menu item.
The output variable is incremented by one whenever a PDO is sent.
ReceiveCounter
RxPDOs feature an additional ReceiveCounter variable under the
Status
menu item.
The input variable is incremented by one whenever a PDO is received. In this way newly arrived PDO are
always logged, even if the data in the PDO are unchanged. The variable nevertheless indicates whether a
device still sends data on a regular basis. It is useful to link variable with the PLC and monitor it.