39
7638897 - v0
2
- 14032016
7 Commissioning
Fig.20 Consultation function
7.3.7 Consultation function
SET
TEMP
TIME
OFF
TIME
ON
MODE
TIME
OFF
TIME
ON
CLOCK
CANCEL
Press 3s
for unlock
ECONOMY MODE
HYBRID MODE
E-HEATER MODE
ON/OFF
NIE-B-058
ECONOMY MODE
Y
HYBRID MODE
E-HEATER MODE
A
A
SET
TEMP
TIME
OFF
TIME
ON
SET
TEMP
1
Press the
CLOCK
and
CANCEL
buttons simultaneously.
The appliance switches to maintenance and repair mode and the
consultation function can be accessed.
2
Press the arrows to show the operating parameters one by one
(refer to the table below).
No.
Left hand figure
under hours
Right hand
figure under
hours
Left hand figure
under minutes
Right hand
figure under
minutes
Temp.
Description
1
t
5
L
Temp.
Water temperature in the tank
2
t
4
Temp.
Ambient temperature
3
t
3
Temp.
Evaporator temperature
4
t
h
Temp.
Intake temperature
5
t
P
Temp.
Air return temperature
6
t
r
Temp.
Difference in return temperature
7
Pulse
Current pulse
of the electronic pressure release
valve
8
X
X
Current
Compressor
Electric resistor
Compressor and electric resistor
9
X
Operating mode
1 Economic mode
2 Hybrid mode
4 Electric water heater mode
8 OFF mode
10
F
X
Fan speed:
F0 OFF
F1 Slow
F2 Average
F3 Fast
11
d
X
Anti-legionella function:
0 Not available
1 Available
12
M
X
Selecting the input power of the
electric resistor:
0 2150 W
1 3200 W
2 1070 W
3 1550 W
-- No electric resistor
13
1
X
X
Last error code
14
2
X
X
First error code
15
3
X
X
Second error code
16
Y
Y
M
M
DD
Software version