Installation in an enclosed space:
Fig.9
Position and location of the
thermodynamic water heater
300
600
300
NIE-C-022
●
To ensure adequate access and facilitate maintenance, allow sufficient
space around the appliance.
The water heater must be placed in a space with a volume of more than
20 m
3
in which the air flow is unhindered.
For example, a room with a ceiling height of 2.50 m, 4 m in length and 2 m
wide presents a volume of 20 m
3
.
The air flow rate is 350 m
3
/h.
Fig.10 Position to be allowed
for the thermodynamic water heater
NIE-C-023
V >15m
3
300
min.
min.
300
min.
600
min.
300
A
0 552
SPC 180 ECO
A (mm)
1670
■
Ventilation
●
Respect the minimum dimensions given in the diagram opposite.
●
Respect the distances on either side of the water heater and between
the back of the appliance and the internal wall of the premises.
■
Premises:
Unheated room at a temperature > 5°C, insulated from the heated rooms
in home.
Example: Garage, boiler room, basement...
Recommendation: room in which the temperature is higher than 10°C all
year round.
Note
Minimum ceiling space of 400 mm.