- 44 -
Country
Categories
Gas type
Gas pressure
(mbar)
RO
Romania
II
2H3B/P
G20 - G30/G31
20 - 30/30
SE
Sweden
II
2H3B/P
G20 - G30/G31
20 - 30/30
SI
Slovenia
II
2H3B/P
G20 - G30/G31
20 - 30/30
SK
Slovakia
II
2H3B/P
G20 - G30/G31
20 - 30/30
TR
Turkey
II
2H3B/P
G20 - G30/G31
20 - 30/30
In the event of deviations from the values given above, proper functioning of the
device is not guaranteed.
Jet and burner properties
Usage*
LPG
Gas category
I
3B/P
(30)
I
3+
(28-30/37)
I
3+
(50)
Gas type
G30
G30
G31
G30
Burner
By
Pass
mm
Power
kW
(g/h)
Jet
mm
Power
kW (g/h)
Jet
mm
Power
kW (g/h)
Jet
mm
Power
kW
Jet
mm
Quick
burner
0.44
3,0
(218)
0,85
3,0
(218)
0,85
3,0
(214)
0,85
3,0
0,75
Standard
burner
0.34
1,75
(127)
0,65
1,75
(127)
0,65
1,75
(125)
0,65
1,75
0,58
Efficient
burner
0.29
1,0
(72,7)
0,50
1,0
(72,7)
0,50
1,0
(71,0)
0,50
1,0
0,43
Triple
ring
0.64
3,7
(269)
0,95
(F4)
3,7
(269)
0,95
(F4)
3,7
(264)
0,95
3,7
0,76
Gas pressure
G30:29 mbar
G30: 29 mbar
G31: 37 mbar
G30: 50
mbar