- 45 -
Usage*
LPG
LPG
Gas category
II
2ELL3B/P
I
2H
I
2L
I
3+
(50)
Gas type
G25
G20
G25
G110
Burner
By
Pass
mm
Pow
er
kW
Jet
mm
Power
kW
Jet
mm
Power
[kW]
Jet
mm
Power
[kW]
Jet
mm
Quick
burner
0,44
3,0
1,34(F3)
3,0
1,18(Y)
3,0
1,21(F2)
3,0
2,6(3)
Standard
burner
0,34
1,75
1,01(Y)
1,75
0,97(Z)
1,75
0,94(Y)
1,75
1,9(2)
Efficient
burner
0,29
1,0
0,82
1,0
0,72(X)
1,0
0,72(F1)
1,0
1,45(1)
Triple
ring
0,64
3,7
1,42(F2)
3,7
1,40(S)
3,7
1,42(K)
3,7
3,5(13)
Gas pressure
G25: 20
mbar
G20:20 mbar
G25: 25 mbar
G110: 8 mbar
*reference values: gas temperature 15 °C, air pressure 1013.26 mbar
5. Installation and operation
5.1 Installation instructions
CAUTION!
Any installation, connection and maintenance related to the device can be
performed only by a qualified, certified technician, according to international,
national and local laws.
5.1.1 Location
Discard the complete packing material after unpacking the device.
Place the device on a dry, level, water- and heat-resistant surface capable of
supporting the device weight with its maximum load with food products designed for
heating.
Never
place the device on the flammable surfaces.
The installation place must be easily accessible and sufficiently spacious to allow
easy operation of the appliance and good air circulation.