- 46 -
Never
place the device directly next to walls, furniture or other objects made of
flammable materials. Keep a minimum distance of
150 mm
from the side and rear
walls. Keep a minimum distance of
600 mm
between the upper surface of the
device and surfaces located above it.
If it is not possible to observe the above mentioned distances, apply protective
measures (e.g. heat-resistant coatings), that can resist temperatures of at least
65 °C
.
Regulate the level and height of the device with adjustable feet. Excessive differences
in height or level may have a negative impact on the device’s operation.
Never
place the device in a damp or wet areas.
Before starting operations remove the protective film from the appliance. Remove the
film slowly in order not to leave the glue residues. Any glue residues may be removed
with use of a suitable solvent.
CAUTION!
Never remove the rating plate or any warning signs from the appliance.
5.1.2 Ventilation
CAUTION!
In accordance with regulations, the device can only be installed in spaces
equipped with permanent ventilation, which prevents the accumulation of
exhaust products harmful to health.
The space where the device is to be installed
must
be of sufficient air capacity for the proper
combustion of gas. Proper combustion requires
an airflow of
at least 2 m
3
/h per kW
of power
rating (see the device's rating plate for
information).
Air intake must from directly from the outside via
permanent openings or circulation channels
connected to a space containing clean air.