GENERAL INFORMATION
This manual is generic in nature and covers a wide range of heating and cooling products manufactured
by Bard Manufacturing Company. It is intended to be a general guide for care and operation of typical
systems and covers the most important features you should be aware of and are responsible for as the
user of the equipment.
Because our product offerings are so varied and can be equipped with many features and options, it is
not possible to cover all aspects of what your specific system may be configured for. Some systems
may be quite simple in features to provide basic cooling and possibly heating, while others may also
incorporate various ventilation technologies, dehumidification circuits, and many different internal controls
as well as room temperature controls. Therefore, you should request a detailed operation sequence
and explanation of any special features from your installer and/or Service Company, and also have them
instruct you as to any routine maintenance procedures you are responsible for.
This manual will address the basic items that should apply to all systems, and will then be separated into
specific types of products to cover things unique to those product types.
AIR FILTERS
Keeping clean air filter(s) is the single most important responsibility of the user of the equipment. Each
type of system must be equipped with an air filter(s) in the indoor circulating air system to clean the
air, to keep the system itself clean for peak efficiency and capacity, and to prolong the useful life of the
equipment. DO NOT operate the system without the proper air filters.
Filters should be inspected at least monthly, and replaced or cleaned (depending on type) as needed.
The useful life of an air filter can vary widely depending upon application and use of the equipment, and
it is critical to monitor filter condition and establish an acceptable maintenance schedule. Failure to do so
will increase operating and repair costs, decrease capacity and efficiency, and shorten the service life of
the equipment. A common symptom of a dirty filter in the cooling mode is a freeze-up of the indoor coil.
The air filters used may be a disposable (throwaway) type or may be a cleanable type that can be
thoroughly cleaned, rinsed and reused many times. It is important to make sure that the correct filter
size and type for your system is always used. If there is any question as to acceptable filter size or type,
review the Installation Instructions for the specific equipment involved, if available. Otherwise, consult
with your installing dealer or Service Company.
Most equipment can have the filters inspected and serviced by the user with no problems. In some
instances, because of equipment design or specific installation conditions, it may be necessary to have
this procedure done by a qualified service company. Have your installer or service company show you
where the filter(s) are and demonstrate the service procedure or make arrangements for them to provide
this service on an as needed basis.
OUTDOOR COIL
The outdoor coil must be kept clean and free of any airborne debris, which can accumulate over time.
Large volumes of air are circulated over the coil, and airborne debris such as lint, dust, materials shed
from trees, paper or other types of airborne material that can become airborne can collect on the entering
coil surface.
The outdoor coil must dissipate heat during the cooling mode, and for a heat pump must also absorb
heat during the heating mode. If the coil is dirty and matted with debris, the airflow across the coil will
be reduced causing poor performance, increased operating run time and associated utility bills, and in
extreme conditions can shorten the useful life of the equipment.
Содержание MULTI-TEC W18AAPA
Страница 2: ......
Страница 31: ......
Страница 77: ......
Страница 80: ......
Страница 84: ...Manual 2110 1442E Page 4 of 11 FUNCTIONAL COMPONENTS SEXP 177 A 1 10 11 12 5 3 4 8 7 7 2 9 6 13 ...
Страница 99: ...Manual 2100 479 Page 6 of 11 FIGURE 1 TYPICAL AIR CONDITIONING SYSTEM COOLING CYCLE MIS 369 ...
Страница 100: ...Manual 2100 479 Page 7 of 11 FIGURE 2 TYPICAL HEAT PUMP SYSTEM COOLING CYCLE MIS 368 ...
Страница 105: ......