8. Technical data 47" version (LCN-47, LCS-47)
8-2 ___________________________________________________________Barco - LC series - R5976934 - user's manual - Revision 08 - April 2008
8.4
Operating conditions
Characteristic
specification
Storage temperature
-20°C - +60°C | -4°F – 140°F, at max. 90% RH, non-condensing
Operating ambient temperature
+5°C – +40°C | 41°F – 104°F, at max. 90% RH, non-condensing
Table 8-4
8.5
CCFL (Cold Cathode Fluorescent Lamp) characteristics (ambient temperature (25 ±2)°C)
Characteristic
Typ. value
Lamp voltage
1750 VRMS
Lamp current
6 mARMS
Lamp starting voltage
2350 VRMS (0°C), 2150 VRMS (25°C)
Lamp life time
50,000hrs *)
Operating frequency
40-70 KHz
Table 8-5
The life time of a lamp is defined as when the brightness is larger than 50% of its original value and the effec-
tive discharge length is longer than 80% of its original length.
8.6
Interfaces
8.6.1
Video IN (Composite Video)
Item
specification
Signal level
1.0Vpp
Connector type
RCA Jack
Termination
75
Ω
Table 8-6