probe. If the measure is not correct it is necessary to replace the temperature probe.
2. disconnect the temperature probe and check the wiring insulation between signal wire
and ground wire (towards control board);
3. replace control board.
Presence of alarm with hot motors:
1. If temperature value (you can read it from display or via PC) seems correct, verify if
the motor stator case are clean
Motor current offset alarm
-
Eye alarm code: 15 for right drive motor
16 for left drive motor
36 for pump motor
-
Alarm level: 1
-
Alarm cause: non-zero phase currents when you turn lift truck on.
In case of motor current offset alarm, follow this procedure:
1. replace the cable connecting the malfunctioning inverter to control board.
2. replace inverter.
3. replace main board.
Main breaker fault
-
Eye alarm code: 17
-
Alarm level: 1
-
Alarm cause: overcurrent on main breaker coil.
In case of alarm follow this procedure:
1. replace main breaker
2. replace control board .
Watchdog timer alarm
-
Eye alarm code: 18
-
Alarm level: 1