PUMP TEST MENU
Following items appear in Pump menu
front panel:
• Voltage on lift command circuit
• Hydraulic lift circuit pressure
• Pump motor current : you can select
current phase from pop-up menu
• Module temperature: you can select
measure unit between °C and °F.
Notice: temperature above 60°C is signalled by a red colour;
temperature above 90°C is signalled by a flashing display.
• Request RPM and motor speed, with an arrow signalling direction
• Motor temperature: you can select measure unit between °C and °F.
Notice: in case of an overheating alarm, the corresponding green
led becomes red.
• Weight present on the forks
• Buzzer and electro valves output status
• Customizable input switches status
• Tilt, lift and high lift digital input status
• Encoder diagnostic leds, both for A and B
Содержание KBET15
Страница 1: ......
Страница 2: ...https www truck manuals net Maintenance Manual ...
Страница 3: ...KION Baoli Jiangsu Forklift Co Ltd KB 2017 08 V1 0 ...
Страница 5: ...Definition of travel direction https www truck manuals net A Forwards I Backwards S Left D Right ...
Страница 6: ...Overall dimensions for four wheel truck ...
Страница 7: ...three wheel truck technical data ...