DATA LOGGING
With this menu (Fig. 42) you can save on file the values of a certain number of variables with
a certain frequency.
The resulting file,
logging.out
, is saved in
<
EYEPLUS PATH
>\
EYEPLUS
\out directory.
This file format is:
FIRST ROW
: name of
NMAX
variables to be
saved followed by saving date and time;
SUCCESSIVE ROWS
:
NMAX
recorded values separated by space.
Data acquisition procedure is following:
1.
Select
Nmax
, the number of variables you want to save
2. Select the variables whose value you want to record, with apposite pop-up menu
3. You can modify sampling period, expressed in seconds.
4.
Pressing
START
button, saving procedure begins; in that phase you can’t modify
acquisition parameters
During acquisition procedure (Fig. 43),
following data are visualized:
A led signals saving instant
Indication of number of saved frames
Flashing message SAVING...
To stop saving procedure you can press
START
button, or simply exiting the menu.
FLASH PROGRAMMING