Method
Action
Result
SET
Button
5
Set the Mode switch to ADJ.
Display: Red - Signal Level; Green -
Threshold
Remote Input 6
No
action
is required; sensor is ready for
the Two-Point TEACH method
2. Teach the
first
condition.
Method
Action
Result
SET
Button
a. Present the
first
condition.
b. Click the SET rocker
button.
Display: Flashes "2Pt tch" then holds on
"1234 2nd"
Remote Input
a. Present the
first
condition.
b. Single-pulse the remote input.
T
3. Teach the second
condition.
Method
Action
Result
SET
Button
a. Present the second
condition.
b. Click the SET rocker
button.
TEACH Accepted
Displays alternate "PASS" and % Minimum
Difference
7; Sensor returns to Adjust
mode
TEACH Not Accepted
Displays alternate "FAIL" and % Minimum
Difference
7; Sensor returns to Adjust
mode
Remote Input
a. Present the second
condition.
b. Single-pulse the remote input.
T
4. Return to Run mode.
Method
Action
Result
SET
Button
Move the Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No
action
is required; sensor returns to
RUN mode
automatically
3.5.2 Dynamic TEACH
• Teaches
on-the-fly
• Establishes a single switching threshold
• Threshold can be adjusted using "+" and "-" rocker
button
(Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing
conditions,
taking
multiple
samples of the light and dark
conditions
and
automatically
setting
the threshold at the
optimum
level.
5 SET
Button:
0.04 seconds
≤
"Click"
≤
0.8 seconds
6 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
7 See
on page 25 for more
explanation
of the % Minimum
Difference
displayed
after
the Two-Point TEACH method.
DF-G3 Long Range Expert
™
Dual Display Fiber
Amplifier
www.bannerengineering.com - Tel: 763.544.3164
17