Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Dark SET:
Note: TEACH
Selection
must be programmed to dr SEt.
1. Enter Adjust Mode.
Method
Action
Result
SET
Button
17
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 18
No
action
required; sensor is ready for Dark
SET method
2. SET Sensing
Condition.
Method
Action
Result
SET
Button
•
Present sensing
condition
•
Click the SET rocker
button
Threshold
Condition
Accepted Displays
read "dr SEt" then alternate "PASS" with %
Offset
19; Sensor returns to Adjust mode
Threshold
Condition
Not Accepted
Displays read "dr SEt" then alternate
"FAIL" with minimum %
Offset
19 for
sensing
condition;
Sensor returns to Adjust
mode
Remote Input
•
Present sensing
condition
•
Single-pulse the remote input
T
3. Return to RUN Mode.
Method
Action
Result
SET
Button
Move Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No
action
required; sensor returns to RUN
mode
automatically
3.5.6
Calibration
SET
• Sets a threshold exactly at the presented
condition
• Threshold can be adjusted using "+" and "-" rocker
button
(Manual Adjust)
A single sensing
condition
is presented, and the sensor
positions
a threshold exactly at the presented
condition.
When a
condition
lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO
setting.
17 SET
Button:
0.04 seconds
≤
"Click"
≤
0.8 seconds
18 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
19 See
on page 25 for more
explanation
of the %
Offset
displayed
after
the Dark SET method
DF-G3 Long Range Expert
™
Dual Display Fiber
Amplifier
www.bannerengineering.com - Tel: 763.544.3164