BA230
37
UK
MOTOR 1 DECELERATION
SPEED 1
MOTOR 2 FORCE
MOTOR 2 DECELERATION
SPEED 2
F2
F5
F6
Adjusts motor 1 thrust during deceleration phase.
0001 = minimum force.
0010 =maximum force.
Adjusts motor 2 thrust.
0001 = minimum force.
0010 =maximum force.
Adjusts motor 2 thrust during deceleration phase.
0001 = minimum force.
0010 =maximum force.
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
MENU H: TIMES ADJUSTMENTS AND SETTINGS
Menu
Function
MOTOR 1 OPENING TIME
Description
Leaf 1 opening time. (*) Tmax 300 s.
All times can be set in steps of 1 s.
MOTOR 1 CLOSING TIME
Leaf 1 closing time. (*) Tmax 300 s.
MOTOR 1
DECELERATION TIME
Leaf 1 operating time in deceleration mode. (*) Tmax 100 s.
MOTOR 2 OPENING TIME
Leaf 2 opening time. (*) Tmax 300 s.
MOTOR 2 CLOSING TIME
Leaf 2 closing time. (*) Tmax 300 s.
MOTOR 2
DECELERATION TIME
Leaf 2 operating time in deceleration mode. (*) Tmax 100 s.
LEAF 2 PHASE SHIFT TIME
IN OPENING
Delays the start in opening of leaf 2 with respect to leaf 1.
In the case of double sliding gate, the time H7 will not be considered.
Tmax 100 s.
LEAF 1 PHASE SHIFT TIME
IN CLOSING
Delays the start in closing of leaf 1 with respect to leaf 2. In the case of double sliding
gate, the time H8 will not be considered.
Tmax 100 s.
AUTOMATIC CLOSING
PAUSE TIME
Determines the pause time in opening before the automatic closing.
Tmax 300 s.
PEDESTRIAN OPENING TIME
Determines the pedestrian opening time. Tmax 300 s.
AUTOMATIC PEDESTRIAN
CLOSING PAUSE TIME
Determines the pause time in pedestrian opening before automatic closing.
Tmax 300 s.
Allows the setting of a number of cycles (o closing) before the maintenance
request.
The value set will always be multiplied for 10.
If 0000 is set, the numbering is excluded.
When the set number of cycles is reached, the maintenance request is signalled by a
slow blink of 60 sec. at the end of the movement.
WARNING:
Every time you enter the menu H12, the cycles numbering is reset and
starts again.
CYCLES NUMBER
Allows the input of the installer code to customize the settings in the programming
phase.
The INSTALLER CODE is the only way to enter the programming menu.
WARNING:
in case of loss of the installer code, it will be possible to delete the old one
by pressing simultaneously the keys + and - for 3 s when the writing PASS appears.
In this way, all the existing settings are erased and the default ones are automatically
set. Only the settings of the performed cycles are still stored in memory.
INSTALLER CODE
SOFTWARE VERSION
Shows the firmware version installed on the equipment. (R__XX)
H15
(*) time must be sufficient to reach the limit switches
NUMBER OF PERFORMED CYCLES
Number of performed cycles. The value displayed on the LCD is increased every 10
movements.