BA230
26
UK
25
FCAM2
Limit switch input opens motor 2 (N.C.).
If not used, disable during the programming phase.
Motors and primary transformer protection
6 A
FAST
Low tension and accessories protection
315 mA
FAST
F1
F2
JP4
PHOTOCELL 2 input (N.C.).
If not used, disable during the programming phase.
Operation:
Input enabled during both opening and closing.
If intercepted, it stops the motion immediately and holds it stopped until the photocell is
freed. Upon release, motion always starts in opening.
If intercepted when the gate is closed, following a Start command it does not allow the
opening of the gate: this will be signalled with 5 fast flashes, then the warning light turns
on to indicate that the door is not in stand-by. Upon release, the gate will start opening
without further commands.
If intercepted during pause, it reloads the pause time.
27
PH2
Multitasking input
External watch:
SEE PROGRAMMING C16-C17-C18
28
SAFETY DEVICES input (see menu C9)
If not used, disable during the programming phase.
Operation:
Input enabled during both opening and closing.
It stops and inverts the motion for 2 s. The gate will remain locked until the next Start
pulse, which will make it start in the obstacle-freeing direction.
If the input is enabled when the door is in stand-by, after a Start or a Pedestrian command
the door will not move and 3 long flashes (2 sec.) will signal the fault.
If the input is enabled when the door is in pause, the door does not close automatically (if
automatic closing is enabled) and 3 long flashes (2 sec.) will signal the fault.
THE EDGE ENABLING IS SIGNALLED BY THE WRITING “SAF” ON THE LCD.
29
COSTA
RISERVA
PHOTOCELL 1 input (N.C.).
If not used, disable during the programming phase.
Operation:
Input enabled only during closing. It stops and inverts the motion, opening the gate
completely. If the gate is closed, it does not affect its functioning.
If intercepted during pause, it reloads pause time (if C2 disabled).
It can be enabled to manage FAST CLOSING.
31
PH1
COMMON INPUTS - OUTPUTS
32
COM
ANTENNA BRAID input
33
GND
ANTENNA SIGNAL input
34
ANT
JP6
Connector for plug-in radio receiver
JP7
Limit switch input closes motor 2 (N.C.).
If not used, disable during the programming phase.
26
FCCM2
Description
Position
Value
Type
PROTECTION FUSES
Not used
30