LED STATUS

ON

OFF

PED (NO)

FCA

 M1 (NC)

ST

OP

 (NC)

FCA

 M2 (NC) 

FCC M2 (NC) 

PHOT

O  2 (NC)

RISER

VA

COST

A (NC)

CCOST

A (NO)

PHOT

O 1 (NC)

COM

FCC M1 (NC)

ST

ART (NO)

20 21 22 23 24 25 26 27 28 29 30 31 32

JP4

24Vdc 3W MAX

+24Vcc

+24Vcc

13 14 15 16 17 18 19

JP5

GND

ANT

JP2

PHASE

NEUTRAL

SW1

SW2

SW3

SW4

JP6

RX

 M1

 M2

MOT

OR 

CLOSE

LAMP

MOT

OR

OPEN

LAMP

MOT

OR

COM

MOT

OR 

CLOSE

MOT

OR

OPEN

MOT

OR

COM

JP5

COM EL

 

EL1 

EL2 

GND

SPIA

 

24Vcc

SEC

JP1

C8

RL1

RL2

L1

C2

CF1

CF3

RL4

RL5

RL3

RL6

RL7

CF4

CF2

CF6

CF5

U2

U5

BA230

CM2

CM1

DL1

DL2

DL3

DL4

DL5

DL6

DL7

DL8

DL9

DL10

DL1

1

DL12

PED 

ST

ART 

FCA

 M1

ST

OP

 

FCA

 M2 

FCC M2 

PHOT

O  2

RISER

VA

COST

A

CCOST

A

PHOT

O 1

COM

FCC M1

JP4

CF7

CF8

CF9

CF10

JP7

EARTH

EARTH

230 V

ac

230 V

ac

1

2

3

4

5

6

7

8

9

10 11 12

13 14 15 16 17 18 19

20 21 22 23 24 25 26 27 28 29 30 31 32

33 34

230V

ac 40W MAX

F1

F2

G:B:D:021G1

LCD1

BA230

Содержание GiBiDi BA230

Страница 1: ...BA230 I UK F E GR D P NL BA230 AS05550 Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS...

Страница 2: ...i S r l se reserva el derecho de modificar los datos t cnicos sin previo aviso en funci ndelaevoluci ndelproducto POR FAVOR LEER CON ATENCI N ESTE MANUAL ANTES DE PROCEDER CON LA INSTALACI N Dieses Pr...

Страница 3: ...OSE LAMP MOTOR OPEN LAMP MOTOR COM MOTOR CLOSE MOTOR OPEN MOTOR COM JP5 COM EL EL1 EL2 GND SPIA 24Vcc SEC JP1 C8 RL1 RL2 L1 C2 CF1 CF3 RL4 RL5 RL3 RL6 RL7 CF4 CF2 CF6 CF5 U2 U5 BA230 CM2 CM1 DL1 DL2 D...

Страница 4: ...start pulse the motion restarts in the obstacle freeing direction SEPARATE SAFETY DEVICES POWER SUPPLY The connection to this power supply will allow the TEST of the devices before the motion Connect...

Страница 5: ...away from children since they pose a potential risk The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitable f...

Страница 6: ...OPEN Common motor 2 11 COM Motor 2 connection closing 12 CLOSE JP5 Negative electrical lock 13 COM Positive 12 Vdc motor 1 electrical lock 14 EL1 Positive 12 Vdc motor 2 electrical lock 15 EL2 Negati...

Страница 7: ...tion Inputenabledduringbothopeningandclosing It stops and inverts the motion for 2 s The gate will remain locked until the next Start pulse whichwillmakeitstartintheobstacle freeingdirection Ifthe inp...

Страница 8: ...willbeloaded onlytheperformedcyclessettingsremainstored PresstheESCkeytogobacktostep1 4figuresappearonthedisplay 0000 thefirstoneisflashing With the or keys the user selects the first digit of the in...

Страница 9: ...onthedisplay lettersACFHE theAis flashing Use the or keys to select the other menus the relative letter will blink PressOKtoentertheselectedmenu intheexample menuA Usethe or keystoenterthesubmenus A1...

Страница 10: ...seethesettingofanumericvalue Usethe and toselectthemenuH itwillblink PressOKtoenterthemenu Use the or keys to select the submenus Press key to enter the selected submenu Thestoredvalueappears withthef...

Страница 11: ...bletheinput TheNwillappearnexttoE1 Usethe and keystoenterthefollowingorthepreviousmenu PressESCtoleavethemenu ACFHE isnowshownonthedisplay E2 PHOTOCELL2 PressOKinsequenceto Enabletheinput theYwillappe...

Страница 12: ...IC LOCK 2 output see diagram 12 Vdc output Thecourtesylightoutputis3 minutestimed TheactivationofthismenuautomaticallydisablesA5 1 MOTOR CONFIGURATION A4 Y MENU A SYSTEM CONFIGURATION AND OPERATING LO...

Страница 13: ...te Pedestriancommandisuninfluentialinopeningandinpause Inclosing itopensbothleaves TheactivationofthismenuautomaticallydisablesA6 A8 A9 ItenablestheSTEPBYSTEPWITHSTOPLogic Operation Start NextStart Ne...

Страница 14: ...given the electroniccircuitistested relay triac etc If an anomaly is detected it will be indicated by 4 long flashes 2 sec of the flashing light The test must be performed when the motors are connect...

Страница 15: ...TEST See also menu C20 LIMIT SWITCHES DECELERATIONS WATER HAMMER C4 C5 C6 C7 Y E1 Y1 Y1 Y2 E2 Y2 N Y3 N Disablesthesafetydevicestest N The exclusion of SAFETY DEVICE by mean of the menu E3 excludes t...

Страница 16: ...ation with the same setting of menusF2andF6 During the PEDESTRIAN closing the PHOTO1 PHOTO2 PEDESTRIAN STARTcommandwillcausethecompleteopening Flashinglightfixedoutput DisablestheRESERVEinput NC N YF...

Страница 17: ...safety devices is cut off for 0 5 and then restored if the photocell 1 input opens and immediately returns NCthe motorsstart otherwise a fault will besignalledby4blinks 1sec oftheflashinglight Enables...

Страница 18: ...IC CLOSING PAUSE TIME Determines the pause time in opening before the automatic closing Tmax 300 s PEDESTRIAN OPENING TIME Determines the pedestrian opening time Tmax 300 s AUTOMATIC PEDESTRIAN CLOSIN...

Страница 19: ...means of sequences of START pulses Select the menu C21 to enter this procedure menu C21 blinking The times learning procedure starts by pressing OK menu C21 Y fixed then TIMES MANAGEMENT TIMES LEARNI...

Страница 20: ...instalment is configured as double sliding the motors will move as indicated in the procedure with the phase shift in opening and closing During normal working phase shifts are zeroed RESET FLASHING...

Страница 21: ...ENERAL AND PEDESTRIAN AUTOMATIC CLOSING ENABLED N FAST CLOSING DISABLED C3 Y PREFLASHING ENABLED C4 N SAFETY DEVICES TEST DISABLED C5 E1 LIMIT SWITCH ENABLED single pair C6 N DECELERATIONS DISABLED C7...

Страница 22: ...ections improper connection may be harmful to both the control unit and the operator 2 Check proper position of the limit switches POWER THE DEVICE 3 Check that the red LEDs of the normally closed con...

Страница 23: ...re Go to menu C6 to program slowdowns Use the dedicated menus to adjust each time parameter Press ESC to exit programming Check whether the force used by operators on the gate is either sufficient or...

Страница 24: ...products ELECTRONIC CONTROL UNIT BA230 are in conformity with the following CEE Directives EMC Directive 2004 108 CE and subsequent amendments and that the following harmonised standards have been ap...

Страница 25: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC6509 02 2009 Re...

Отзывы: