BA230
35
UK
Enables the edge provided with n.c. contact (normally closed).
Runs the safety test on the n.c. edge if enabled with menu C4 - E3.
Disables the courtesy light.
Sets T3 as the time set for the deceleration with the same setting of
menus F1 and F5.
During the PEDESTRIAN closing, the PHOTO1-PHOTO2-
PEDESTRIAN command will determine only the pedestrian opening.
The START will cause complete opening.
Blinking flashing light output (slow blinking in opening, fast in closing).
Enables the RESERVE input for the connection of an external watch.
Operation:
If the contact on the RESERVE input is closed, following a START
command the door opens but does not close automatically. When the
contact closes, after the pause time the door will close automatically.
When the door is open, closing can be started with a START command if
the menu enabled is STEP-BY-STEP or STEP-BY-STEP WITH STOP.
CAUTION:
remember to set automatic closing.
Sets T3 as the time set for the deceleration with the same setting of
menus F2 and F6.
During the PEDESTRIAN closing, the PHOTO1-PHOTO2-
PEDESTRIAN-START command will cause the complete opening.
Flashing light fixed output.
Disables the RESERVE input.
NC
N
YF
Y
Y
Y
YS
N
N
N
Enables the edge with 8K2 in series resistance.
Runs the safety test on the 8K2 edge (check the correct resistive value)
if enabled with menu C4 – E3.
Enables the courtesy light working on motor 2 output .
If the installation has 2 motors the courtesy light will not be active
COURTESY LIGHT 230 Vac (see diagram).
Timed 3 min after the motors motion end.
Enables the courtesy light working on electrical lock 2 output
COURTESY LIGHT 12 Vdc.
Timed 3 min after the motors motion end.
T3 excluded.
SAFETY DEVICE
COURTESY LIGHT
T3 ADDITIONAL TIME
INVERSION FROM PEDESTRIAN
FLASHING LIGHT
EXTERNAL WATCH,
CLOSING ALLOWED
DISABLED
C9
C11
C13
C14
C15
C16
C10
8K2
Y1
Y2
N
If decelerations are enabled, the pulse is given at the end of the
deceleration time.
The final stroke is not managed by the safety devices.
Disabled with sliding configuration and with dead man logic
FINAL STROKE IN OPENING
AND CLOSING
C8
Y
Disables the closing final stroke function.
N