BA230
25
UK
ELECTRICAL CONNECTIONS: FASTON
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
CF1 - CF3
CF2 - CF4
CF5 - CF6
CF7 - CF8
CF9 - CF10
5
4
3
2
1
Primary connection of 230Vac transformer (black cables)
Secondary connection of 14Vac transformer (red cables)
Secondary connection of 22Vac transformer (blue cables)
Motor 2 capacitor connection
Motor 1 capacitor connection
Descrizione
JP1
Morsetto
Power supply 230Vac
1
Posizione
Segnale
PHASE
Power supply 230Vac
2
NEUTR
Ground wire connection
Ground wire connection
3
4
GND
GND
JP2
Flashing light output 230Vac 40W
5
LAMP
Flashing light output 230 Vac 40W
6
LAMP
Operation:
Fast flashing during opening, off during pause,
slow flashing during closing
Motor 1 connection 1 (opening)
7
OPEN
Common motor 1
8
COM
Motor 1 connection 1 (closing)
9
CLOSE
Motor 2 connection (opening)
10
OPEN
Common motor 2
11
COM
Motor 2 connection (closing)
12
CLOSE
JP5
Negative electrical lock
13
COM
Po12 Vdc motor 1 electrical lock
14
EL1
Po12 Vdc motor 2 electrical lock
15
EL2
Negative external accessories power supply
16
GND
Warning light 24 Vdc 3W max
17
SPIA
Operation:
Slow flashing during opening, fixed light during
pause, fast flashing during closing.
External accessories (photocells, radio…) +24Vdc power supply
18
+ ACC
External safety d24Vdc power supply.
CAUTION: output present only during the operating cycle
19
+ SAF
JP4
START (N.O.) input
20
START
21
PED
STOP input (N.C.).
If not used, jump with terminal n° 32
22
STOP
PEDESTRIAN input (N.O.) (It opens for the time set in menu H10).
WARNING
After an emergency intervention with motion intervention of the second leaf, the
pedestrian command will start both motors.
Limit switch input opens motor 1 (N.C.).
If not used, disable during the programming phase.
23
FCAM1
Limit switch input closes motor 1 (N.C.).
If not used, disable during the programming phase.
24
FCCM1