BA24
35
UK
The symbols shown at the beginning reappear.
In this case, the +, - and OK buttons have the following meanings:
+ » START
- » PEDESTRIAN
OK » STOP
ESC
OK
-
+
25
Gbd
Description
Menu
Function
State
SWING GATE /
OVERHEAD DOOR / BARRIER
A2
Y
It configures the system for a sliding gate.
This configuration automatically excludes:
• gate phase shifts in opening and closing
• hammer stroke
• 2 seconds final opening and closing stroke.
• T3 additional time
NOTE: the limit switches are NOT activated automatically, choose the
best configuration with the menu C5
SLIDING GATE
A3
Y
It configures the system for one motor.
With this setting, the outputs for the electrical lock 2 can be used for
a 3 minutes timed courtesy light 24V max 10W.
The activation of this menu automatically disables A5.
1 MOTOR CONFIGURATION
A4
Y
MENU A: SYSTEM CONFIGURATION AND OPERATING LOGIC SELECTION
KEY + :
enters the following menu A1-A2-A3…
KEY - :
enters the previous menu A3-A2-A1…
KEY ESC:
leaves the menu
KEY OK:
enables Y (yes). It activates the function, and automatically disables the complementary function
(example: The activation of A4 = 1 motor automatically disactivates A5 = 2 motors).
It configures the system for swing gate, overhead door or barrier.
The activation of this menu automatically disables A3.
It configures the system for two motors.
The activation of this menu automatically disables A4.
2 MOTORS CONFIGURATION
A5
Y
Содержание Gi.Bi.Di. BA24
Страница 173: ...IP55 2 10A 3 mm 2 5 mm 0 5 mm N C N A 2 1 2 3 BA24 173 GR...
Страница 190: ...START 1 2 START 2 1 START 1 C21 Y OK C6 H3 H6 ESC Gbd H3 H6 T3 T3 T3 AP CH BA24 190 GR...
Страница 191: ...24V 24V 20 21 Vdc 4 s 16V 4 s 3 PASS 5 2 start 3 start 3 start 4 1 4 1 4 4 3 N C 3 N C 2 8K2 BA24 191 GR...
Страница 196: ...NOTE BA24 196...
Страница 197: ...NOTE BA24 197...
Страница 198: ...NOTE BA24 198...